INSTALLATION CLEARANCES   

COMBUSTIBLE CONSTRUCTION      NON-COMBUSTIBLE CONSTRUCTION   

Back:                                   

6”                                                            0”   

Sides:                                 

6”                                                            0”   

 

INSTALLATION CODES AND STANDARDS 

 

The griddle must be installed in accordance with:   

In the United States of America:   

State and local codes.   

National Fuel Gas Code, ANSI-Z223.1/NFPA #54 (latest edition). This shall include but not be limited to: 

NFPA #54 Section 10.3.5.2 for Venting. Copies may be obtained from The American Gas Association 
Accredited Standards Committee Z223,    @ 400   
 

N. Capital St. NW, Washington, DC 20001 or the Secretary Standards Council, NFPA, 1 Batterymarch Park 
Quincy, MA 02169-7471   
NOTE: In the Commonwealth of Massachusetts All gas appliances vented through a ventilation hood or 
exhaust system equipped with a damper or with a power means of exhaust shall comply with 248 CMR.   

3. NFPA Standard # 96 

Vapor Removal from Cooking Equipment

, latest edition, available from the National Fire 

Protection Association, Batterymarch Park, Quincy, MA 02269.   

In Canada:   

  Local codes.   

CAN/CSA-B149.1 Natural Gas Installation (latest edition)       

CAN/CSA-B149.2 Propane Installation Code (latest edition), available from the Canadian Gas 

Association, 178 Rexdale Blvd., Etobicoke, Ontario, Canada M9W 1R3   
 

GRIDDLES MOUNTED ON STANDS WITH CASTERS 

 

Griddles  mounted  on  stands  with  casters  must  use  a  flexible 
connector  (not  supplied)  that  complies  with  the  Standard  for 
Connectors for Movable Gas Appliances ANSI Z21.69•CSA6.16, and 
a  quick-disconnect  device  that  complies  with  Gas  Fuel,  ANSI 
Z21.3•CSA6.9. In addition, adequate means must be provided to limit 
movement of the appliance without depending on the connector and 
the  quick-disconnect  device  (or  its  associated  piping)  to  limit 
appliance movement. Attach the restraining device at the rear of the 
griddle as shown in Fig. 1.                                                                                       

Fig. 1 

 

If  disconnection  of  the  restraint  is  necessary,  turn  off  the  gas  supply  before  disconnecting.  Reconnect  the 
restraint prior to turning the gas supply on and returning the griddle to its installation position.   

Casters  are  only  supplied  on  a  griddle  stand.  If  the  griddle  is  moved  for  any  reason  the  griddle  should  be 
re-leveled (see LEVELING in this manual).   

 

Summary of Contents for SRTG Series

Page 1: ...information for your local service company This manual contains important safety instructions which must be strictly followed when using this equipment Please retain this manual for future reference...

Page 2: ...al A pressure regulator designed to operate with the griddle has been supplied and must be installed before the griddle is placed into service Refer to GAS PRESSURE REGULATOR INSTALLATION in this manu...

Page 3: ...rk Quincy MA 02269 In Canada 1 Local codes 2 CAN CSA B149 1 Natural Gas Installation latest edition 3 CAN CSA B149 2 Propane Installation Code latest edition available from the Canadian Gas Associatio...

Page 4: ...commercial type Flexible Connector with the net inside diameter I D as large as or larger than the gas pipe inlet on this appliance Codes require that a gas shutoff valve must be installed in the gas...

Page 5: ...gas operation The burner and pilot orifices required to convert the griddle to propane gas are shipped with the griddle in the shipping packaging It is recommended that a trained gas service technici...

Page 6: ...the entire griddle surface to create a thin film Wipe off any excess oil with a cloth Repeat the procedure until the griddle has a slick mirror like finish This will also help reduce the sticking of...

Page 7: ...er etc while viewing thru the pilot sight hole 4 When the gas at the pilot has been burning for about 45 seconds release the safety valve button If the pilot does not remain lit repeat the operation a...

Page 8: ...zone and allows cooking a wide variety of products over a single griddle plate The chart below is a suggested usage of zone cooking When zone cooking it is suggested that you start with your lowest te...

Page 9: ...s AFTER EACH USE Clean the griddle with a wire brush or flexible spatula ONCE PER DAY Thoroughly clean the griddle back splash sides and front Remove empty and wash the grease drawer in the same manne...

Page 10: ...tabilize allowing the burner to cycle ON and OFF at least two times 3 Watch for burner to cycle OFF then measure the temperature for that zone The temperature should be 350 F 15 F If not continue to S...

Page 11: ...me SHUTDOWN OF GRIDDLE 1 Turn thermostats to the OFF position to cut off burners 2 The pilots will remain lit and monitored by the safety valve as long as the main gas supply is on EXTENDED SHUTDOWN 1...

Reviews: