14
Function Interface
PANEL FUNCTIONS & DESCRIPTIONS
8
§Lift TIG control panel
1. Welding mode button
: Press it to select TIG Lift welding mode.
2. L parameter knob
: Rotate it to adjust welding current. In functional parameter
interface, rotate it to select parameters.
3. R parameter knob
: Rotate it to adjust Down Slope time and other parameters.
4. Functional parameter button
.
5. Cooling mode button
: Press it to select water cooling mode.
TIG functional parameter interface:
1. Trigger mode
: 2T or 4T.
2. Down slope time
: 0~10s.
3. Post flow time
: 0~10s.
1. Trigger mode:
2T or 4T.
2. Down slope time:
0~10s.
3. Post flow time:
0~10s.