15
Pin number
Output
1; 3; shield
-V
2; 4
+V
Wire gauge is AWG18 or 0.82mm² per pin.
8.3 Cable length
With 12V power supply the maximum length of extension power cable must not
exceed 7.5 m, the wire gauge must be 4 x AWG18 + shield to comply with the
KYCON connector.
8.4 Regulation requirement
The equipment must be compliant with safety, EMC country regulations.
Customers may need to re-confirm that the whole system complies with the EMC
and safety directives.
In case the Base station is connected to mains by its electrical cable, the electrical
plug must be easily reachable in order to remove the cable.
In case the electrical plug is not easily reachable it is mandatory to have a circuit
breaker system easily accessible for any technician in order to switch off
completely the installation.
9 CONNECTIVITY
9.1 Primary
The base station only accepts the dynamic host configuration protocol (DHCP) on
the ETH interface. For example: ADSL,
4G…
Please refer to the provider
’s manual.
9.2 Secondary
The base station can be connected via the 3G or 4G network with the USB dongle
provided by Sigfox.