EAN-FLIR Cameras
© SightLine Applications, Inc.
16
7
NUC/FFC Command
The Tau, Quark and Boson often need to be calibrated. This is done by applying a Non-Uniformity
Correction (NUC) using Flat Field Correction (FFC) processes.
Before Calibration After Calibration
Figure 17: Calibration Example
Table 1: Camera COM Protocols
Camera Type
Baud
Data Bits
Stop Bits
Parity
Tau
57600
8
1
none
Boson
921600 8
1
none
IMPORTANT
: Before starting the process and sending FFC commands, place an object of uniform
density and temperature in front of the camera lens.
to send FLIR protocol messages to the camera. From the Panel
Plus main menu »
File
»
Send Command
.
Figure 18: Send Command
7.1
Tau and Quark Cameras
7.1.1
1500-OEM or 3000-OEM: Cam0/Vin0/Serial2
1.
Panel Plus main menu »
Configure
»
Serial Ports
.
2.
Set
Serial Port 2
to
57600
baud. Set the
Protocol
field to something other than
Port Not Used
.
3.
Go to
File
»
Send Command
.