EAN-FLIR Cameras
© SightLine Applications, Inc.
21
3.
Disable
Video Send
:
51,AC,18,3D,00, 8E, 00, 00, 00, 00, DF, 00, 06, 00, 04, FF, FF, FF, FF, 00, 00, 00, 00, D9, C2, AE, 23
•
51,AC = SightLine header
•
18 = Packet length (23 decimal)
•
3D = command pass through
•
00 = serial port 0
•
8E ... AE = Boson command
•
23 = SLA checksum
4.
Enable
Video Send
:
51,AC,18,3D,00, 8E, 00, 00, 00, 00, DF, 00, 06, 00, 04, FF, FF, FF, FF, 00, 00, 00, 01, C9, E3, AE,E3
8.2
RHP-BOSON Interface Module - 4000-OEM USB Connection
The 4000-OEM can also be connected directly to the 640 Boson camera through the RHP-BOSON VPC
TTL interface module
and the J8 USB-C port on the 4000-OEM. For additional USB camera information
see the
The custom cable harnesses included in the kit provides:
•
External power
•
3.3V TTL serial communication for command and control
•
USB for video streaming
Figure 20: RHP-BOSON VPC TTL Interface Module - 4000-OEM USB Connection
Network Switch
or PC Direct
SLA-CAB-1504 (J50)
SLA-CAB-0504 (J2)
SLA-CAB-0403 (J4)
4000-OEM
6-pin JST to USB
RJ45 Ethernet
SLA-PWR-B12V-36W
SLA-CAB-TC2-USB (J8)
FLIR Boson 640 with RHP-BOSON
VPC TTL Interface Module
7-pin JST Pigtail