EAN-FLIR Cameras
© SightLine Applications, Inc.
14
•
Set
Baud
to
57600
.
•
Data Bits
,
Stop Bits
, and
Parity
are set at default values shown.
Figure 13: Tau Camera Serial Port Settings
2.
After configuring the settings, changed fields will be highlighted in red. Click
Send
.
3.
To save the configuration to the
parameter file, from the Panel Plus main
menu »
Parameters
»
Save to board
.
In 3.01.xx and earlier software versions,
saving the Serial Port settings will prompt
an additional dialog window. Some
setting changes require the board to be
restarted for the settings to take effect. In
the Apply New Settings dialog window,
select an option to save the port
configuration.
Figure 14: Apply New Settings Dialog - 3.01.xx and Earlier
4.
See
Appendix C - Virtual Com Port Setup
EAN-Ethernet-and-Serial-Communication
virtual COM port.
6.3
Tau SWIR Camera
The Tau SWIR camera and the Tau LWIR camera setup and configuration are the same. When
connecting the FLIR Camera Control GUI to the Tau SWIR camera the baud rate must be set to 57600.
The FLIR Camera Control GUI version must be 1.21 or later. The FLIR GUI must be configured in SWIR
mode (menu
Camera
»
Select
) before connecting to the camera. The Tau SWIR can also be setup with a
Camera Link adapter.
To get the Camera Link video, use the
Generic Digital
configuration for Tau with the following changes:
1500-OEM Init code:
InitCameraLink
3000-OEM Init code: None