EAN-FLIR Cameras
© SightLine Applications, Inc.
27
Figure 28: Tau Camera 100-Ohm Resistor Location
10.3
Boson Video or Serial Communication Issues - FPC/FFC
Most issues encountered with the Boson camera are the result of a damaged FPC connector (
Figure
29
).
Serial passthrough to the Boson camera from the 3000-OEM is enabled in software release 2.25.07
(and later).
Figure 29: Damaged FPC Connector
10.4
Reset Boson Cameras to Factory Defaults
Both the Boson 320 and 640 cameras can be reset to factory defaults using serial passthrough and the
FLIR Boson Application GUI.
Contact your FLIR representative to obtain a copy of this application.
5.
Set up a TCP passthrough and virtual COM port to allow camera control through the FLIR Boson
Application. See the
6.
Launch the FLIR camera control application. Go to
System
»
Camera Configuration
.
7.
In the
Camera Configuration
section click
Restore Factory Defaults
.
8.
Reset the connection and reconnect to the FLIR camera. The FLIR camera should now be reset to
factory defaults.
Resistor
Location
7
8