Copyright ©Sigicom AB 2018
11
Note!
The dBG standard, ISO7196:1995, clause A.5 says:
“if there is low freq. data dominantly, recommended integration time
constant is 10s”.
S51 only has 1s time constant for the dBG standards so it is
recommended to set a longer interval time (10-60 s) and primarily
use the Leq data instead of Lmax in this case, and only use Lmax
data if when frequecies closer to the upper 20Hz band is the main
contributor.
3.4
Level ranges
S51 Sound Level Meter handles the level ranges:
•
20-95 dBA
•
25-95 dBC
•
30-105 dBA/dBC
•
40-115 dBA/dBC
•
55-130 dBA/dBC
•
40-114 dBG
•
50-124 dBG
•
65-139 dBG
One of the level ranges can be selected at a time.
3.5
Display devices
S51 Sound Level Meter shall be connected to the INFRA Field
Monitoring System which has several capabilities of displaying the
measured signals. The resolution is 0.1 dB.