Copyright ©Sigicom AB 2018
17
4.4
Parameters
4.4.1 Standard selection
There are totally 18 selectable
standards
, which is the same as
combinations of the parameters:
•
acoustic quantity
•
time weighting
•
level range
•
frequency weighting
Standard
Acoustic
quantities
Time
weighting
Level range and
Frequency weighting
S01
L
max
and L
eq
FAST
20 - 95 dBA
S02
L
max
and L
eq
FAST
30 – 105 dBA
S03
L
max
and L
eq
FAST
40 - 115 dBA
S04
L
max
and L
eq
FAST
55 - 130 dBA
S05
L
max
and L
eq
FAST
25 - 95 dBC
S06
L
max
and L
eq
FAST
30 - 105 dBC
S07
L
max
and L
eq
FAST
40 - 115 dBC
S08
L
max
and L
eq
FAST
55 - 130 dBC
S09
L
peak
and L
eq
PEAK
60 - 130 dBA
S10
L
peak
and L
eq
PEAK
60 - 130 dBC
S11
L
max
and L
eq
SLOW
20 - 95 dBA
S12
L
max
and L
eq
SLOW
30 - 105 dBA
S13
L
max
and L
eq
SLOW
40 - 115 dBA
S14
L
max
and L
eq
SLOW
55 - 130 dBA
S15
L
max
and L
eq
SLOW
25 - 95 dBC
S16
L
max
and L
eq
SLOW
30 - 105 dBC
S17
L
max
and L
eq
SLOW
40 - 115 dBC
S18
L
max
and L
eq
SLOW
55 - 130 dBC
S22
L
max
and L
eq
SLOW
40-114 dBG
S23
L
max
and L
eq
SLOW
50-112 dBG
S24
L
max
and L
eq
SLOW
65-139 dBG