Copyright © Sigicom AB 2021
21
5.
Operation
5.1.
Startup
To turn the C20 on, press
. The display is lit up and the unit is ready for
use. See section 2.2 for a description of start-up sequence. If the access
code is activated, see section 5.9 for more information.
The following options are available:
•
Start monitoring as described in section 5.2.
•
Initiate a manual communication to INFRA Net,
see section 5.4.2.
•
Open the GUI menu, see section 5.8.
Instrument errors, if present, will be indicated at bottom right on the main
screen and should be addressed prior to monitoring. See section 5.8.7.
If last known monitoring mode was ON, the C20 will automatically restart
monitoring after instrument start-up.
5.2.
Start Monitoring
To start monitoring
2
, press
. The display will indicate the mode
transition and its steps:
1.
First a sensor test will be done (see 5.2.1). This takes a few
seconds, and the monitoring symbol is yellow during this phase.
2.
Monitoring is started, indicated with a flashing green symbol.
After transition into monitoring mode, the instrument will communicate to
INFRA Net and transmit its status.
Note! Any key stroke while in monitoring mode may cause a
disturbance in the measuring result.
2
In previous INFRA systems, Monitoring is called registration (REGON).