SDG7000A Quick Start 13
Front Panel Operation
Shortcut Buttons
Press the Burst / Mod / Sweep button to
quickly turn on/off the burst/modulation/sweep function
and jump to the corresponding parameter setting page.
When the function is turned on, the corresponding button
light is on;
Press the AWG / I/Q button to quickly switch the
waveform to arbitrarily waveform/vector signal and jump
to the corresponding parameter setting page. When the
waveform is selected, the corresponding button light is on;
Press the Digital button to quickly turn on / off the digital bus output and jump
to the corresponding parameter setting page. When the digital bus is turned on,
the corresponding button light is on;
Press the Waveform button to quickly recall the waveform selection menu;
Press the Utility button to quickly recall the system setup menu.
Numeric Keypad and Knob
Use the numeric keypad to directly enter the
value and order of magnitude of the selected
parameter. For example, to set the frequency
to 1 GHz, press the keys 1 and G/n in
turn. If the order of magnitude is 1 (100), you
can press Enter directly.
In addition to directly typing parameter
values with the numeric keypad, you can also
use the knob to realize continuous
adjustment of parameters. Press the knob on
the selected parameter box and press the
button
◀
and
▶
below the knob to
select the digit to be adjusted, and then
rotate the knob clockwise to increase the
value or counterclockwise to decrease the
value.