will display on the bottom left and top left of the screen when you move the cursor.
To do manual cursor measurements, follow these steps:
1.
Press CURSOR button to enter the cursor function menu.
2.
Press the “Cursor Mode” option button to select “Manual”.
3.
Press the “Type” option button to select “Voltage” or “Time”.
4.
Press the “Source” option button to select “CH1”, “CH2”, “CH3”,
“CH4”,“MATH”, “FFT”, “REFA” ,“REFB” ,“REFC”, “REFD” according to
input signal channel.
5.
Select “Cur A”, turn the “Universal” knob to adjust Cursor A.
6.
Select “Cur B”, turn the “Universal” knob to adjust Cursor B.
7.
The measurement values are displayed on the top of the left corner:
If the measurement type is set to “Voltage”, the values are:
The value of Cur A: CurA
The value of Cur B: Cur B
The voltage increment between Cursor A and Cursor B:
△
V
If the measurement type is set to “Time”, the values are:
The value of Cur A: CurA
The value of Cur B: Cur B
The time increment between Cursor A and Cursor B: T
△
The reciprocal of time increment between Cursor A and Cursor B: 1/ T
△
Picture 2.11-2