Front of Oscilloscope 

 

 

Touch  Screen  Display 

The 

display  and  major  functions 
area. See "User Interface" for 
more details 

 

 

USB 2.0 Host Ports 

Connect 

to  USB  storage  devices  for 
data 

transfer 

or 

USB 

mouse/keyboard for control 

 

Front  Panel 

Includes  knobs 

and buttons. See "Front Panel" 
for more details 

 

 

Digital Input Connector 

 

Analog Input Connectors 

 

Probe 

Compensation 

Ground Terminal 

 

 

Power Switch 

 

Supporting Legs 

 

 

   

 

 

 

Summary of Contents for SDS2000 Series

Page 1: ...SDS2000X HD Series Digital Storage Oscilloscope Quick Start EN01A ...

Page 2: ......

Page 3: ... change parts of or all the specifications or pricing policies at the company s sole decision Information in this publication replaces all previously corresponding material Any method of copying extracting or translating the contents of this manual is not allowed without the permission of SIGLENT Note SIGLENT is the registered trademark of SIGLENT TECHNOLOGIES CO LTD ...

Page 4: ...YRIGHT INFORMATION I GENERAL SAFETY SUMMARY 1 SAFETY TERMS AND SYMBOLS 2 GENERAL CARE AND CLEANING 3 GENERAL INSPECTION 4 QUICK START 5 FRONT OF OSCILLOSCOPE 7 BACK OF OSCILLOSCOPE 8 PROBE COMPENSATION 9 USER INTERFACE 10 BASIC OPERATIONS 17 ...

Page 5: ...ect the Signal Cable Correctly The potential of the signal cable ground is equal to the earth ground Do not connect the signal wire to a high voltage Look Over All Terminals Ratings To avoid fire or electric shock please look over all ratings and sign instructions of the instrument Before connecting the instrument please read the manual carefully to gain more information about the ratings Use Prop...

Page 6: ...ly the Specified Fuse Do Not Operate Without Covers Do not operate the instrument with covers or panels removed Safety Terms and Symbols Terms used in this product These terms may appear in the product DANGER Indicates direct injury or hazards that may happen WARNING Indicates potential injury or hazards that may happen CAUTION Indicates potential damage to the instrument or other property that ma...

Page 7: ...egularly in accordance with its operating conditions 1 Disconnect the instrument from all power sources and then clean with a soft wet cloth 2 Clean the loose dust on the outside of the instrument and probe with a soft cloth When cleaning the LCD take care to avoid scratching it To avoid damage to the surface of the instrument and probe please do not use any corrosive liquid or chemical cleansers ...

Page 8: ...ll be responsible for damages to the instrument resulting from shipment SIGLENT would not provide free maintenance or replacement if the instrument has been damaged in shipment 2 Inspect the instrument If there are instruments found damaged defective or failure in electrical and mechanical tests please contact SIGLENT 3 Check the accessories Please check the accessories according to the packing li...

Page 9: ...SDS2000X HD Quick Start 5 Quick Start Mechanical Dimension Front View Top View ...

Page 10: ... as stands to tilt the oscilloscope upwards for stable placement as well as easier operation and observation of the instrument Connecting to Power Supply The standard power supply for the instrument is 100 240 V 50 60 Hz Please use the power cord provided with the instrument to connect it to AC power ...

Page 11: ...r Interface for more details USB 2 0 Host Ports Connect to USB storage devices for data transfer or USB mouse keyboard for control Front Panel Includes knobs and buttons See Front Panel for more details Digital Input Connector Analog Input Connectors Probe Compensation Ground Terminal Power Switch Supporting Legs ...

Page 12: ...remote control Built in Waveform Generator Output USB 2 0 Host Connect with a USB storage device or USB mouse keyboard Auxiliary Out Outputs the trigger indicator When Mask Test is enabled outputs the pass fail signal AC Power Input Handle 100M LAN Port Connect the port to the network for remote control ...

Page 13: ...connect the CH1 Input Terminal and the Compensation Signal Output Terminal on the front panel Connect the ground alligator clip of the probe to the Ground Terminal under the compensation signal output terminal 2 Check the displayed waveforms and compare them with the following figure Under Compensated Compensated Correctly Over Compensated 3 Use a nonmetallic flat head screwdriver to adjust the lo...

Page 14: ...ers of the corresponding traces Touching the boxes creates a dialog box Timebase and Trigger Descriptor Boxes show the parameters of timebase and trigger respectively Touching the boxes creates a dialog box Dialog Box is the main area to select the parameters for a chosen specific function Trigger Delay Indicator locates where the trigger is on the horizontal axis Trigger Level Indicator shows the...

Page 15: ... Input Impedance Vertical Scale Vertical Offset Bandwidth Information Probe Attenuation Factor Timebase and Trigger Descriptor Boxes Trigger delay Horizontal scale timebase Samples Sample Rate Trigger source Trigger coupling Trigger mode Trigger level Trigger type Trigger slope ...

Page 16: ...selected function Title bar Touching the bar can hide the dialog box and touching again can open the dialog box Parameter setting area Scroll bar When parameters are more than the displayed range the blue scrollbar will be displayed By sliding the dialog area up and down or rolling the mouse wheel it can scroll to the area not displayed ...

Page 17: ...ct the expected option from the pop up list Virtual Keypad Sets parameters with a numerical value Touch the parameter region and the parameter can be adjusted by the universal knob on the front panel touch the region again then the virtual keypad appears To use the operation of setting deskew of the channel as an example If the expected value is 65 ns input 65 on the virtual keypad and then choose...

Page 18: ...touch gestures in the grid area Drag the waveform left and right to move it on the horizontal axis Pinch and spread the waveform horizontally to re scale the timebase Drag the waveform up and down to move it on the vertical axis Pinch and spread the waveform vertically to re scale the vertical gain ...

Page 19: ...it Touch and drag the cursor information region to move the pair of cursors simultaneously Draw a rectangular box to create a zone or a histogram region At the beginning of the gesture keep the angle close to 45 so it can be recognized as the drawing box gesture ...

Page 20: ...ion is more quickly achieved Automatically sets the waveform to adapt the display according to its frequency and amplitude Resets the oscilloscope to the default configuration Enables or disables the touch screen When it is lighted the functionality is enabled Rotate the universal knob to set the value of the activated parameter or to move the selected cursor Push to select a different cursor Choo...

Page 21: ...n to disable the channel From the Touch Screen Touch the button and then select the expected channel to turn it on and its channel descriptor box and the dialog box will appear on the display Touch the channel descriptor box and then touch the Off button to disable it Vertical System Analog channel on off Digital channels on off Math on off Reference on off Rotate the knob to adjust the vertical s...

Page 22: ...ertical scale and to decrease Check to coarsely adjust the vertical scale and uncheck to enable fine adjustment Touch the region to set the offset with the universal knob or virtual keypad to increase the offset and to decrease Set the offset to zero Copy the setting of the current channel to another channel Quickly select the current channel as the source of a specified operation Trigger FFT Meas...

Page 23: ...D Bandwidth limit Full 200 MHz or 20 MHz Probe attenuation 1X 10X 100X or custom Set the label text Click to recall the label setting Users can customize the text and display of the label Quickly apply a specified operation Cursor Measure FFT Search DVM Histogram and Mask Test to the current channel Impedance Units for the channel Deskew Enable disable invert Trace visible hidden ...

Page 24: ...is displayed in real time Rotate to adjust trigger delay push to set trigger delay to zero Touch the timebase descriptor box to display a quick dialog box Timebase and Trigger Delay can also be set in this dialog box Set the horizontal scale timebase by the virtual keypad to increase and to decrease the horizontal scale Set the trigger delay by the virtual keypad to increase and to decrease the tr...

Page 25: ...bar Acquire Menu to recall the Acquire dialog box on the right side Select the interpolation mode Select the Acq mode Select the acquisition mode Normal Peak Average ERES Select the Memory Management mode Auto Fixed Sample Rate and Fixed Memory Select the maximum memory depth Enter the sequence menu XY mode on off ...

Page 26: ...witch between the main window and zoom window Currently activated window is high lighted by dash line In Zoom mode the grid area is divided into two areas The main window appears on the top and the zoom window on the bottom The region without the gray background in the main window is the portion of trace that is magnified in the zoom window Please refer to the User Manual for detailed operation in...

Page 27: ...eriod if no valid trigger occurs Single mode triggers once when all conditions are met Normal mode triggers repeatedly when all conditions are met Trigger level adjustment push to set the level to 50 of the waveform Ready LED lighted when ready for trigger Trig d LED lighted when a trigger event happens Indicators Relative to Trigger Trigger level Indicator Horizontal 0 position Indicator Horizont...

Page 28: ... Slope and other specific types Set holdoff None Time Events Set trigger coupling mode DC AC LF Reject HF Reject Enable disable Noise Rejection When Noise Reject is on the trigger hysteresis is increased so the noise immunity of the trigger circuit is better As a compromise the trigger sensitivity degrades Set the Zone trigger ...

Page 29: ... 25 Math Touch Func1 Func2 or push the button on the front panel to create a math trace and open math setup dialog box Math trace Math setup dialog box Selects the trace F1 F2 Selects the operator and source C1 C4 Z1 Z4 F1 F2 ...

Page 30: ...r push the button on the front panel to open measure setup dialog box Measurement parameters and statistics display area If select the mode as Simple the Simple parameter area is displayed Touch the button on the front panel to reset the statistics Measure dialog box ...

Page 31: ... Vertical or Horizontal axis of a trace or both For more information please refer to the User Manual Push the button to open the cursors setup dialog box Rotate the knob to move the selected cursor push to select different cursor The display mode of cursors Following Fixed ...

Page 32: ... traces Press the button on the front panel to set the reference waveforms Select the location of the reference REFA REFB REFC REFD Select the source C1 C4 and Math Enable disable Display of the reference waveform Set the label text of the reference trace Save the waveform specified in to the specified location in The reference waveforms ref can be saved to an external storage device See Save Reca...

Page 33: ...e waveform Choose Save or Recall operation Select the object type Recall the File Manager for further operations File Manager Quickly Save Push the button on the front panel to perform specified save action The default is to save a screenshot as a picture bmp png jpg Touch Utility Save Button to set the file type and path ...

Page 34: ...ration Warm up the oscilloscope for at least 20 minutes prior to each use or calibration in order for it to reach a stable operating temperature Specifications are not guaranteed during the warm up period Whenever the oscilloscope is used in an environment outside 23 5 C or when it has been more than one month since the previous calibration a self calibration is recommended Quick Cal When Quick Ca...

Page 35: ... Quick Cal Touch Utility Menu Maintenance Quick Cal to set Quick Cal Software Option Installing a Software Option Follow the steps below to install a software option see the data sheet for details after purchasing it and obtaining the Option Key 1 Utility Menu Software Options 2 Select the correct Option Type 3 Input the option key in the text box 4 Touch Install and then restart the oscilloscope ...

Page 36: ...Since its first oscilloscope was launched in 2005 SIGLENT has become the fastest growing manufacturer of digital oscilloscopes We firmly believe that today SIGLENT is the best value in electronic test measurement Headquarters SIGLENT Technologies Co Ltd Add Bldg No 4 No 5 Antongda Industrial Zone 3rd Liuxian Road Bao an District Shenzhen 518101 China Tel 86 755 3688 7876 Fax 86 755 3359 1582 Email...

Reviews: