SIG
L
ENT
146
SDS2000X-E
User Manual
Save Type
The oscilloscope supports setups, waveforms, pictures and CSV files storage. The default
save type is setups.
1. Setups
The default storage type of the oscilloscope. Setups store the settings of the oscilloscope
in internal or external memory. Setup files terminate with “*.set” file extension. At most 20
setting files (from No.1
~
No.20) can be stored to internal memory. The stored settings can
be recalled.
2. Reference
The oscilloscope saves the waveform data in external memory with the “*.ref” file
extension. The data of the channel is you select channel. At recall, the data will be
displayed on the screen by REFA or REFB.
3. BMP
The oscilloscope saves the screen image in external memory with the “*.bmp” file
extension. You can specify the file name and saving directory under the same directory
using the same file name. The recall of images is not supported.
4. JPG
The oscilloscope saves the screen image in external memory with the “*.jpg” file extension.
You can specify the file name and saving directory under the same directory using the
same file name. The recall of images is not supported.
5. PNG
The oscilloscope saves the screen image in external memory with the “*.png” file
extension. You can specify the file name and saving directory under the same directory
using the same file name. The recall of image is not supported.
6. Binary
The oscilloscope saves the waveform data in external memory with the “*.bin” file
extension. The data of all the channels turned on can be saved in the same file. The recall
of binary is not supported.
7. CSV
The oscilloscope saves the waveform data in external memory with the “*.csv” file
extension. The stored files contain the waveform data of the displayed analog channels
and the main setting information of the oscilloscope. The recall of CSV files is not
supported.
Set the save type to
CSV
, and set the
Para Save
option to
On
or
Off
to turn on or of the
Summary of Contents for SDS2000X-E Series
Page 1: ...User Manual SDS2000X E Series Digital Oscilloscope UM0102E E01A SIGLENT TECHNOLOGIES CO LTD...
Page 14: ......
Page 69: ...SIGLENT SDS2000X E User Manual 43 Figure 13 x Interpolation Figure 14 Sin x x Interpolation...
Page 98: ...SIGLENT 72 SDS2000X E User Manual Figure 29 Relative Window Trigger...
Page 100: ...SIGLENT 74 SDS2000X E User Manual Figure 30 Interval Trigger...
Page 103: ...SIGLENT SDS2000X E User Manual 77 Figure 32 State Dropout Trigger...
Page 105: ...SIGLENT SDS2000X E User Manual 79 Figure 33 Runt Trigger...
Page 125: ...SIGLENT SDS2000X E User Manual 99 Figure 49 CAN Trigger...
Page 129: ...SIGLENT SDS2000X E User Manual 103 Figure 51 LIN Trigger...
Page 162: ...SIGLENT 136 SDS2000X E User Manual...
Page 200: ...SIGLENT 174 SDS2000X E User Manual Figure 95 Built in Arb interface...
Page 206: ...SIGLENT 180 SDS2000X E User Manual Figure 100 WiFi setting menu...
Page 215: ...SIGLENT SDS2000X E User Manual 189 Figure 108 Option Information...