SIG
L
ENT
SDS2000X-E User Manual
187
Reference Position
The reference position setting determines the physicial point that the oscilloscope uses
during vertical and horizontal scale changes. In some situations, it is more convenient to
use a fixed position on the display.
Press the
Utility
button on the front panel and then press the
Reference Pos.
softkey to
enter the Reference POS menu
.
Press the
Vertical
softkey to select
Fixed Offset
or
Fixed Position
.
Fixed Position
: When the vertical gain is changed, the oscilloscope will keep the vertical
offset level indicator stationary.
Fixed Offset
: When the vertical gain is changed, the oscilloscope will have the vertical
offset level indicator move with the actual voltage level.
Press the
Horizontal
softkey to select
Fixed Delay
or
Fixed Position
.
Fixed Position
: When the time base is changed, the oscilloscope will keep the horizontal
offset indicator stationary.
Fixed Delay
: When the time base is changed, the oscilloscope will have the horizontal
delay indicator move with the trigger point.
Power On Line
Press the
Utility
button on the front panel; then; press the
Power On Line
softkey to
select
Enable
or
Disable.
Enable:
When the oscilloscope is energized, the oscilloscope will start automatically
without user intervention. This is ideal for situations where physical access to the
instrument power switch is difficult or impossible, such as automated test equipment
or remote locations.
Disable
: This setting requires user intervention to energize the scope. Press the
power key at the lower-left corner of the front panel to start the oscilloscope.
Summary of Contents for SDS2000X-E Series
Page 1: ...User Manual SDS2000X E Series Digital Oscilloscope UM0102E E01A SIGLENT TECHNOLOGIES CO LTD...
Page 14: ......
Page 69: ...SIGLENT SDS2000X E User Manual 43 Figure 13 x Interpolation Figure 14 Sin x x Interpolation...
Page 98: ...SIGLENT 72 SDS2000X E User Manual Figure 29 Relative Window Trigger...
Page 100: ...SIGLENT 74 SDS2000X E User Manual Figure 30 Interval Trigger...
Page 103: ...SIGLENT SDS2000X E User Manual 77 Figure 32 State Dropout Trigger...
Page 105: ...SIGLENT SDS2000X E User Manual 79 Figure 33 Runt Trigger...
Page 125: ...SIGLENT SDS2000X E User Manual 99 Figure 49 CAN Trigger...
Page 129: ...SIGLENT SDS2000X E User Manual 103 Figure 51 LIN Trigger...
Page 162: ...SIGLENT 136 SDS2000X E User Manual...
Page 200: ...SIGLENT 174 SDS2000X E User Manual Figure 95 Built in Arb interface...
Page 206: ...SIGLENT 180 SDS2000X E User Manual Figure 100 WiFi setting menu...
Page 215: ...SIGLENT SDS2000X E User Manual 189 Figure 108 Option Information...