SIG
L
ENT
92
SDS2000X-E
User Manual
UART Trigger and Serial Decode
Please read “
Setup for UART Signals
”
,
“
UART Trigger
” and “
UART Serial Decode
” to
trigger and decode the signals.
Setup for UART Signals
1. Press the
Decode
key to enter the
DECODE
function menu.
2. Press the
Decode
softkey and select the desired slot (Decode1 or Decode2).
3. Press
Protocol
softkey and then select
UART
by turning
Universal Knob
.
4. Press
Signal
softkey to enter the
SIGNAL
menu as Figure 43 shows.
Figure 43 UART SIGNAL Menu
5. Set RX:
a. Press
RX
to select the channel that is connected to the RX signal.
b. Press first
Threshold
key
to set the RX signal’s threshold voltage level by
Universal Knob
. The threshold voltage level is for decoding, and it will be used
as the trigger voltage level when the trigger type is set to serial.
6. Set TX:
a. Press
TX
to select the channel that is connected to the TX signal.
b. Press first
Threshold
key
to set the TX signal’s threshold voltage level by
Universal Knob
. The threshold voltage level is for decoding, and it will be used
as the trigger voltage level when the trigger type is set to serial.
7. Press
softkey to return previous menu.
8. Press the
Configure
softkey to enter
BUS CONFIG
menu.
Figure 44
BUS CONFIG Menu
9. Press
Baud
softkey to set baud rate.
The baud rate can be set as predefined value.
If the desired baud rate is not listed, press
Baud
and select
custom
option,
press the
Custom
and turn the
Universal Knob
to set the desired baud rate.
10. Press
Data Length
softkey and set byte bits (5-8) by
Universal Knob
.
11. Press
Parity Check
softkey to set the type of parity check (Even, Odd or None).
12. Press
Stop Bit
softkey to set the length of the stop bit (1, 1.5 or 2 bits).
Summary of Contents for SDS2000X-E Series
Page 1: ...User Manual SDS2000X E Series Digital Oscilloscope UM0102E E01A SIGLENT TECHNOLOGIES CO LTD...
Page 14: ......
Page 69: ...SIGLENT SDS2000X E User Manual 43 Figure 13 x Interpolation Figure 14 Sin x x Interpolation...
Page 98: ...SIGLENT 72 SDS2000X E User Manual Figure 29 Relative Window Trigger...
Page 100: ...SIGLENT 74 SDS2000X E User Manual Figure 30 Interval Trigger...
Page 103: ...SIGLENT SDS2000X E User Manual 77 Figure 32 State Dropout Trigger...
Page 105: ...SIGLENT SDS2000X E User Manual 79 Figure 33 Runt Trigger...
Page 125: ...SIGLENT SDS2000X E User Manual 99 Figure 49 CAN Trigger...
Page 129: ...SIGLENT SDS2000X E User Manual 103 Figure 51 LIN Trigger...
Page 162: ...SIGLENT 136 SDS2000X E User Manual...
Page 200: ...SIGLENT 174 SDS2000X E User Manual Figure 95 Built in Arb interface...
Page 206: ...SIGLENT 180 SDS2000X E User Manual Figure 100 WiFi setting menu...
Page 215: ...SIGLENT SDS2000X E User Manual 189 Figure 108 Option Information...