SIG
L
ENT
102
SDS2000X-E
User Manual
LIN Trigger
This part will provide a brief introduction and description for the operation of the LIN
trigger.
Trigger conditions:
Break
— The oscilloscope will be triggered at the position of the break field’s
break delimiter.
ID
(Frame ID) — The oscilloscope will be triggered at the position of the identifier
field’s stop bit, if the value of a frame’s ID is equal to specified value.
(
Note:
If the data’s value is 0xXX, any data value will be matched.)
ID + DATA
(Frame ID and Data) — The oscilloscope triggers when a frame with
an ID and data equal to the selected values is detected. Use the
Universal Knob
to select the value for the ID, Data1 and Data2.
1) The ID’s value is the same as set value.
2) If you have set either Data1’s or Data2’s value, and the signal has a data is
the same as that value. If you have set both Data1’s and Data2’s value, the
signal should has two consecutive data, the first data’s value is Data1,
second data value is Data2.
(
Note:
If the data’s value is 0xXX, any data value will be matched.)
Data Error
— The oscilloscope will be triggered when errors (such as ID check
error, checksum error, sync byte field error) are detected.
Operation steps:
1. Press
Setup
to enter the
TRIGGER
function menu.
2. Press
Type
and select
Serial
.
3. Press
Protocol
and select
LIN
.
4. Press
Trigger Setting
softkey to enter
LIN TRIG SET
menu.
5. Press
Condition
and select the trigger condition by
Universal Knob
:
If you
select
ID
condition
:
a. Press
ID
softkey and set its value by turning the
Universal Knob
.
If you
select
ID+DATA
condition
:
a. Press
ID
softkey and set its value by turning the
Universal Knob
.
b. Press
DATA1
softkey and set its value by turning the
Universal Knob
.
c. Press
DATA2
softkey and set its value by turning the
Universal Knob
.
Summary of Contents for SDS2000X-E Series
Page 1: ...User Manual SDS2000X E Series Digital Oscilloscope UM0102E E01A SIGLENT TECHNOLOGIES CO LTD...
Page 14: ......
Page 69: ...SIGLENT SDS2000X E User Manual 43 Figure 13 x Interpolation Figure 14 Sin x x Interpolation...
Page 98: ...SIGLENT 72 SDS2000X E User Manual Figure 29 Relative Window Trigger...
Page 100: ...SIGLENT 74 SDS2000X E User Manual Figure 30 Interval Trigger...
Page 103: ...SIGLENT SDS2000X E User Manual 77 Figure 32 State Dropout Trigger...
Page 105: ...SIGLENT SDS2000X E User Manual 79 Figure 33 Runt Trigger...
Page 125: ...SIGLENT SDS2000X E User Manual 99 Figure 49 CAN Trigger...
Page 129: ...SIGLENT SDS2000X E User Manual 103 Figure 51 LIN Trigger...
Page 162: ...SIGLENT 136 SDS2000X E User Manual...
Page 200: ...SIGLENT 174 SDS2000X E User Manual Figure 95 Built in Arb interface...
Page 206: ...SIGLENT 180 SDS2000X E User Manual Figure 100 WiFi setting menu...
Page 215: ...SIGLENT SDS2000X E User Manual 189 Figure 108 Option Information...