Bode Plot
Many devices have frequency dependent performance specifications. For example, a
band-pass filter has a pass band that is defined over a given frequency range. Testing a
devices performance with respect to frequency is also known as a Bode Plot of that device.
The bode plot application for the SDS2000X-E integrates the source and measure
operation and provides a detailed Bode Plot of the device-under-test (DUT).
Note: At this time, the Bode Plot function is only supported by SIGLENT SAG1021 and
SDG generator products.
A Bode Plot consists of a generator or source that sweeps a sine wave across a range of
frequencies while measuring the input to and output from a device-under-test (DUT). At
each frequency, the device gain and phase are measured and plotted on a Bode chart.
Perform Bode Plot
This section gives an overview of the steps you must take when performing Bode Plot
application.
Note: To minimize reflections and maximize accuracy, use 50 ohm BNC through
terminations on the oscilloscope channels.
1. Press the
Utility
on the front panel to enter the UTILITY function menu, and then
press the
Next Page
softkey to enter the second page.
2. Press
Bode Plot
softkey to enter the BODEPLOT function menu, only the
Default
button which on the front panel is valid.
Figure 109 Bode plot menu
3. Configure the parameters (the details see “setting” section).
4. Press
Operate
softkey to select on to perform the test.
Setting
1. Press
Configure
softkey to enter the Configure menu. All the parameters in this
menu are used to configure the external AWG.
Summary of Contents for SDS2000X-E Series
Page 1: ...User Manual SDS2000X E Series Digital Oscilloscope UM0102E E01A SIGLENT TECHNOLOGIES CO LTD...
Page 14: ......
Page 69: ...SIGLENT SDS2000X E User Manual 43 Figure 13 x Interpolation Figure 14 Sin x x Interpolation...
Page 98: ...SIGLENT 72 SDS2000X E User Manual Figure 29 Relative Window Trigger...
Page 100: ...SIGLENT 74 SDS2000X E User Manual Figure 30 Interval Trigger...
Page 103: ...SIGLENT SDS2000X E User Manual 77 Figure 32 State Dropout Trigger...
Page 105: ...SIGLENT SDS2000X E User Manual 79 Figure 33 Runt Trigger...
Page 125: ...SIGLENT SDS2000X E User Manual 99 Figure 49 CAN Trigger...
Page 129: ...SIGLENT SDS2000X E User Manual 103 Figure 51 LIN Trigger...
Page 162: ...SIGLENT 136 SDS2000X E User Manual...
Page 200: ...SIGLENT 174 SDS2000X E User Manual Figure 95 Built in Arb interface...
Page 206: ...SIGLENT 180 SDS2000X E User Manual Figure 100 WiFi setting menu...
Page 215: ...SIGLENT SDS2000X E User Manual 189 Figure 108 Option Information...