When the type is “Edge”, the oscilloscope triggers at the first edge after the
specified edge (Risin
g or Falling) of the qualified source; when the type is “Edge
with Delay”, time limit condition is available.
Qualified
Source
Edge
Trigger
Source
Trigger
Position
Qualified Edge = Rising
Edge = Rising
Touch the
Qualified Setting
region to set the qualified source and threshold;
Touch the
Edge Setting
region to set the edge trigger source, threshold and
slope.
15.5.12
Nth Edge Trigger
Nth edge trigger is similar to an edge trigger with conditions. The trigger is
satisfied after meeting the user-defined idle time and edge number conditions.
As shown in the figure below, when the idle time between the pulse trains is
greater than the specified idle time, it is triggered on the third falling edge of the
pulse train.