SDS5000X Series Digital Oscilloscope User Manual
182
WWW.SIGLENT.COM
A. Touch to specify the baud rate, the range is
500b/s to 5Mb/s
B. Set the Manchester signal's logic type. R:1
indicates that rising edge is used to encode a
bit value of logic 1, and F:1 indicates that falling
edge is used to encode a bit value of logic 1
C. Set the idle level
D. Set the starting edge of the Manchester signal.
The range is 1~32
E. Set the minimum idle time/inter-frame gap time
of the Manchester bus in terms of the bit width.
F. Set the display format to Byte or Bit
G. Set the bit order to MSB or LSB
H. Set the sync field size, from 0 to 32
I. Set the header size, from 0 to 32
J. Set the number of words in data field, from 1 to
255
K. Set the data word size, from 2 to 8
L. Set the trailer size, from 0 to 32
M. Return to previous menu
16.12.2 Manchester Serial Decode
The configuration of Manchester decoding is similar to that of I2C decoding.
Summary of Contents for SDS2000X Plus
Page 1: ...SDS5000X Series Digital Oscilloscope User Manual UM0105X E01E...
Page 2: ......
Page 158: ...SDS5000X Series Digital Oscilloscope User Manual 156 WWW SIGLENT COM Ack Acknowledge bit...
Page 165: ...SDS5000X Series Digital Oscilloscope User Manual WWW SIGLENT COM 163...
Page 240: ...SDS5000X Series Digital Oscilloscope User Manual 238 WWW SIGLENT COM...
Page 248: ...SDS5000X Series Digital Oscilloscope User Manual 246 WWW SIGLENT COM...
Page 361: ...SDS5000X Series Digital Oscilloscope User Manual WWW SIGLENT COM 359...