18.3
Type of Measurement
18.3.1 Vertical Measurement
Vertical measurement includes 19 parameters:
Max:
Highest value in the input waveform
Min:
Lowest value in the input waveform
Pk-Pk:
Difference between maximum and minimum data values
Top:
Value of most probable higher state in a bimodal waveform
Base:
Value of most probable lower state in a bimodal waveform
Amplitude:
Difference between top and base in a bimodal
waveform. If not bimodal, the difference between max and min
Mean:
Average of data values