The following is the peaks of FFT waveform:
Measure the FFT waveform
Press the Cursors button on the front panel to turn on the cursor function, and
then specifying the source as "Math". X1 and X2 cursors can be used to
measure the frequency value at the cursor position.
Only the maximum parameter of the FFT is supported in automatic
measurement.
Note
:
DC components in the signal may show a large amplitude near 0 Hz. If
your application does not require measurement of the DC component, it is
recommended to set coupling mode of the source channel to "AC".