SIGLENT
SSG5000X Programming Guide 105
Range
Return
Boolean
Default
0
Menu
ARB > ARB State
Example
:RADio:ARB 1
3.8.4.2
Select Waveform ([:SOURce]:RADio:ARB:WAVeform)
Command
Format
[:SOURce]:RADio:ARB:WAVeform “<WFM:file_name|SEQ:file_name>”
[:SOURce]:RADio:ARB:WAVeform?
Instruction
This command enables or disables the arbitrary waveform generator
function
Parameter
Type
String
Parameter
Range
Existing segment or sequence
Return
String
Default
*NONE
Menu
ARB > Select Waveform > Select
Example
:RADio:ARB:WAVeform “WFM:SINE_WAVE”
3.8.4.3
Sample Clock ([:SOURce]:RADio:ARB:SCLock:RATE)
Command
Format
[:SOURce]:RADio:ARB:SCLock:RATE <rate>
[:SOURce]:RADio:ARB:SCLock:RATE?
Instruction
This command sets the sample clock rate for the dual ARB format
Parameter
Type
Float, unit: Hz, kHz, MHz, GHz, Default “Hz”
Parameter
Range
0.002 Hz ~ 240 MHz
Return
Float
Default
2 MHz
Menu
ARB > ARB Setup > Sample Clock
Example
:RADio:ARB:SCLock:RATE 4 MHz