Specifications

Max AC Voltage 

125V rms or 175V peak, 100kHz, 

0.3 A  switched, 125VA (resistive load)

Maximum DC Voltage

110V, 1A switched, 30VDC (resistive load) 

Contact Life

100000 operations

at 1A 30VDC(at 0.5 Hz) 

100000 operations

at 0.3A 125VDC (at 0.5 Hz)

Contact Resistance

75 mΩ 

maximum at 6VDC, 1A

Actuation Time

5ms maximum on/off

M a x i m u m   s w i t c h i n g 
voltage

250 VAC, 220 VDC

Maximum switching power

62.5VA / 30W

Insulation Resistance

Minimum 1G ohm 

500VDC

Connector Type

Clamp  terminal, #24 AWG wire size

Prenotion: To avoid breaking the product, please do not pull it away from multimeter when measurement is executed. 

Channel Capabilities

Item

No. of wires

No. of channels

DCV, ACV

[1]

2 wires (H, L)

12  (CH1~CH12)

DCI, ACI

[2]

2 wires (H, L)

4  (CH13~CH16)
(2A Range)

2W Resistance

2 wires (H, L)

12 (CH1~CH12)

4W Resistance

4 wires (Input H, L
+ sense H, L)

6 pairs (CH1 [input]
& CH7 [sense], 2&8, •••, 6&12) 

Capacitance

2 wires (H, L)

12  (CH1~ CH12)

Diode/Continuity

2 wires (H, L)

12  (CH1~ CH12)

Period/Frequency

2 wires (H, L)

12  (CH1~ CH12)

Temp(Thermocouple)
Temp (RTD)

2 wires (H, L)
2 wires (H, L)

12  (CH1~ CH12)
12  (CH1~ CH12)

Remarks:
[1]Voltage range : <125VAC, 110VDC
[2] For continuous current < 2.2A, Accuracy ± (% 3 (reading) + 0.02% (range)). 

Summary of Contents for SC1016

Page 1: ...SC1016 User s Guide...

Page 2: ...s The scanner features 12 multi purpose 4 current channels and supports the following measurement functions DCV ACV DCI ACI 2WR 4WR CAP FREQ DIODE CONT and TEMP RTD and Thermocouple It provides a conv...

Page 3: ...maximum on off M a x i m u m s w i t c h i n g voltage 250 VAC 220 VDC Maximum switching power 62 5VA 30W Insulation Resistance Minimum 1G ohm 500VDC Connector Type Clamp terminal 24 AWG wire size Pr...

Page 4: ...t covered under the warranty 1 Power Off Turn the Power Off and take out the power cord 2 Open the SDM rear panel slot Take off the two screws on the slot corners to remove the optional slot cover Kee...

Page 5: ...urement parameters Start On Off Start or stop scan operation Exit Exit the scanner function 1 Operation mode setup Scan Measures all specified channel ranges Channel MIN MAX for each trigger event Tim...

Page 6: ...for SDM3065X 10M 100M CAP Auto 2nF 20nF 200nF 2 F 20 F 200 F 10000 F 2mF 20mF 100mF for SDM3065X The scanner function provides two measurement speeds Fast 50 reading s and Slow 5 reading s Fast 1PLC S...

Page 7: ...statistics function Set the Inquire Channel by direction keys and the interface displays the minimum average maximum span standard deviation samples and trend chart of measurement results of the sett...

Page 8: ...syDMM software It allows users to easily select the measurement function and range for each channel and start acquiring measurement data With a rich online help system the user is able to create a vir...

Reviews: