SIGLENT Digital Multimeter SC1016 User’s Guide

WWW.SIGLENT.COM

4.Channel setup

Press the [Channel Setup] to enter the setup interface.

Table 2. Scanner Function Menu Description

Function Menu

Description

Channel Config

Open/close the channel and set the measurement function, measurement 

parameters of specified channel.

Low

Set the low value of scanned channel range.

High

Set the high value of scanned channel range.

Press the [Channel Setup] to enter the channel configuration interface and set the channel switch, function, range and speed..

 

The range setting is applicable for the following functions: DC/AC Voltage (DCV/ACV), 2/4 Wire Resistance (2W/4W), Capacitance (CAP), Frequency (FRQ).

Table 3. Available Range for different measurement function

Measurement Function

Available Range

DCV/ACV/ FRQ

Auto, 200mV, 2V, 20V, 200V

DCI/ACI

2A (fixed)

2W/4W

Auto, 200Ω, 2kΩ, 20kΩ, 200kΩ, 2MΩ(1MΩ for SDM3065X), 10MΩ, 100MΩ

CAP

Auto, 2nF, 20nF, 200nF, 2μF, 20μF, 200μF, 
10000μF (2mF, 20mF, 100mF for SDM3065X)

The scanner function provides two measurement speeds: Fast (50 reading/s) and Slow (5 reading/s). (Fast: 1PLC, Slow: 10 PLC for SDM3065X)

The speed setting is applicable for the following functions: DC/AC Voltage (DCV/ACV), 2/4 Wire Resistance (2W/4W)  

Operating instructions:

• Move the cursor to choose the wanted parameter by direction keys and the background color of cursor’s position turns to gray.

• Select the current item by pressing “OK” key and the background color of the selected item turns to green.

• Set the parameter by up and down direction keys.

• Press “OK” key again to store the setting of the selected item of which the background turns back to gray. Move the cursor and repeat the 

prior steps to set the next parameter.

• Press [Done] to save the current settings and return to the higher level menu. 

5.Channel range setting

Select [High] or [Low] and then input numerical value by direction keys.
Note: The upper limit value should be always bigger than the lower limit value.

Summary of Contents for SC1016

Page 1: ...SC1016 User s Guide...

Page 2: ...s The scanner features 12 multi purpose 4 current channels and supports the following measurement functions DCV ACV DCI ACI 2WR 4WR CAP FREQ DIODE CONT and TEMP RTD and Thermocouple It provides a conv...

Page 3: ...maximum on off M a x i m u m s w i t c h i n g voltage 250 VAC 220 VDC Maximum switching power 62 5VA 30W Insulation Resistance Minimum 1G ohm 500VDC Connector Type Clamp terminal 24 AWG wire size Pr...

Page 4: ...t covered under the warranty 1 Power Off Turn the Power Off and take out the power cord 2 Open the SDM rear panel slot Take off the two screws on the slot corners to remove the optional slot cover Kee...

Page 5: ...urement parameters Start On Off Start or stop scan operation Exit Exit the scanner function 1 Operation mode setup Scan Measures all specified channel ranges Channel MIN MAX for each trigger event Tim...

Page 6: ...for SDM3065X 10M 100M CAP Auto 2nF 20nF 200nF 2 F 20 F 200 F 10000 F 2mF 20mF 100mF for SDM3065X The scanner function provides two measurement speeds Fast 50 reading s and Slow 5 reading s Fast 1PLC S...

Page 7: ...statistics function Set the Inquire Channel by direction keys and the interface displays the minimum average maximum span standard deviation samples and trend chart of measurement results of the sett...

Page 8: ...syDMM software It allows users to easily select the measurement function and range for each channel and start acquiring measurement data With a rich online help system the user is able to create a vir...

Reviews: