SDG5000 User Manual 107
3.7. Example 7:Generate a Sweep Linear Wave
Generate a sine sweep waveform whose frequency starts from 100Hz to
10KHz. Use internal trigger mode, linear sweep, and the sweep time is 2s.
Steps:
Set the sweep function:
Press Waveforms and choose the sine waveform as the sweep function.
The default setting of the source is internal.
Set the frequency, amplitude and offset.
1. Press Frequency and choose Frequency which will display in white color.
Input ‘5’ from the keyboard and choose the unit ‘KHz’ to set the frequency
5KHz.
2. Press Amplitude to choose Amplitude which will display in white color.
Input ‘5’ from the keyboard and choose the unit ‘Vpp’ to set the amplitude
5Vpp.
3. Press Offset to choose Offset which will display in white color. Input ‘0’
from the keyboard and choose the unit ‘Vdc’ to set the offset 0Vdc
Set the sweep time.
Press Sweep →More 1 of 2→Sweep Time, Input ‘1’ from the keyboard
and choose the unit ‘s’ to set sweep time 1s.
Set the start frequency
Press Start Freq, Input ‘100’ from the keyboard and choose the unit ‘Hz’