Programming Guide
21
switch >
is Noise, you can set this parameter.
BANDWIDTH
<bandwidth
value>
Value of noise bandwidth. Only when wave type is
noise, you can set this parameter.
Note: if the command does
n’t set basic wave type, WVPT parameter will be set to current
wave type.
where:
<type>:={SINE, SQUARE, RAMP, PULSE, NOISE, ARB ,DC}
<frequency>:= {Default unit is "Hz". Value depends on the model.}
<amplitude>:= {Default unit is "V". Value depends on the model.}
<offset>:= {Default unit is "V". Value depends on the model.}
<duty>:= {0% to 100%. Value depends on frequency.}
<symmetry> :={ 0% to 100%}
<phase>:= {0 to 360,In SDG2000X/SDG1000X,if you set 400,it will set
40(400-360)}
< standard deviation >:= {Default unit is "V". Value depends on the model.}
<mean>:= {Default unit is "V". Value depends on the model.}
<width>:= {Max_width < (Max_duty * 0.01) * period and Min_width >
(Min_duty * 0.01) * period.}
<rise>:= {Value depends on the model.}
<fall>:= {Value depends on the model.}
<delay>:= {Unit is S. Maximal is Pulse period, minimum value is 0.}
<bandwidth switch >:= {ON,OFF}
<bandwidth value>:= {value between 20MHz and 120MHz}
QUERY SYNTAX
<channel>: BSWV (BaSic_WaVe)?
<channel>:={C1, C2}
RESPONSE FORMAT
<channel>:BSWV<type>,<frequency>,<amplitude>,<offset>,
<duty>,<symmetry>, <phase>,<variance>,<mean>,<width>,
<rise>, <fall>, <delay>.
EXAMPLE
Change channel one wave type to ramp.
C1: BSWV WVTP, RAMP
Change frequency of channel one to 2000 Hz.
C1: BSWV FRQ, 2000
Set amplitude of channel one to 3Vpp.
C1: BSWV AMP, 3
Read channel basic wave parameters from device.
C1: BSWV?
Return:
C1: BSWV WVTP, SINE,FRQ,100HZ,PERI,0.01S,AMP,2V,
Summary of Contents for SDG5000 series
Page 38: ...SDG5000 User Manual 27 Figure 2 5 Setting the Offset ...
Page 109: ...SDG5000 User Manual 98 Figure 3 1 Sine Waveform ...
Page 111: ...SDG5000 User Manual 100 Figure 3 2 Square Waveform ...
Page 129: ...SDG5000 User Manual 118 3 12 Figure 3 12 FSK Waveform ...
Page 135: ...SDG5000 User Manual 124 Figure 3 15 DSB AM Waveform ...