Programming Guide
26
Parameter/command
SDG800
SDG1000
SDG2000X
SDG5000
SDG1000x
<channel>
No(single channel)
yes
yes
yes
yes
[type], SRC
no(only internal source)
yes
yes
yes
yes
CARR, DLY
no
yes
yes
yes
yes
CARR, RISE
yes
no
yes
yes
yes
CARR, FALL
yes
n o
yes
yes
yes
[type]:={AM, FM, PM, FSK, ASK, DSBAM, PWM}
3.6 Sweep Wave Command
DESCRIPTION
Sets or gets sweep parameters.
COMMAND SYNTAX
<channel>SWWV(SweepWaVe) <parameter>
<channel>:={C1, C2}
<parameter>:= {a parameter from the table below}
Parameters
Value
Description
STATE
<state>
Turn on or off sweep. Note: if you want to set or
read other parameters you must set STATE to ON
at first.
TIME
<time>
Value of sweep time.
STOP
<stop frequency>
Value of stop frequency.
START
<start frequency>
Value of start frequency.
TRSR
<trigger src>
Trigger source.
TRMD
<trigger mode>
State of trigger output. If TRSR is EXT, the
parameter is invalid.
SWMD
<sweep mode>
Sweep style.
DIR
<direction>
Sweep direction.
EDGE
<edge>
Value of edge. Only when TRSR is EXT, the
parameter is valid.
MTRIG
<manual trigger>
Make a manual trigger. Only when TRSR is MAN,
the parameter is valid.
CARR,
WVTP
<wave type>
Carrier type.
CARR, FRQ
<frequency>
Value of carrier frequency.
CARR, AMP
<amplitude>
Value of carrier amplitude.
CARR,
OFST
<offset>
Value of carrier offset.
CARR, SYM
<symmetry>
Value of carrier symmetry, Only Ramp can set this
parameter.
CARR,
DUTY
<duty>
Value of carrier duty cycle. Only Square can set
this parameter.
CARR,
<phase>
Value of carrier phase.
Summary of Contents for SDG5000 series
Page 38: ...SDG5000 User Manual 27 Figure 2 5 Setting the Offset ...
Page 109: ...SDG5000 User Manual 98 Figure 3 1 Sine Waveform ...
Page 111: ...SDG5000 User Manual 100 Figure 3 2 Square Waveform ...
Page 129: ...SDG5000 User Manual 118 3 12 Figure 3 12 FSK Waveform ...
Page 135: ...SDG5000 User Manual 124 Figure 3 15 DSB AM Waveform ...