Noise Rejection
Noise Reject adds additional hysteresis to the trigger circuitry. By increasing the trigger
hysteresis band, you reduce the possibility of triggering on noise. However, this also
decreases the trigger sensitivity so that a slightly larger signal is required to trigger the
oscilloscope.
Press the
Setup
button on the front panel, and then press the
Noise Reject
softkey
continually to set the option to
On
or
Off
to turn on or off the noise rejection function.