SPS5000X series service manual
Current Readback resolution
1
mA
Temperature coefficient
200ppm/°C from rated output current following 30-minute warm-up.
ppm/
℃
Protection Function
OVP
Setting Range
4-44
V
Setting Accuracy
± (2% of rated output voltage)
OCP
The maximum output current limit of the front output terminal is 10A.
Setting Range
3-30
6-60
9-90
3-30
A
Setting Accuracy
± (2% of rated output current)
OTP
Over temperature alarm and shut off output.
Low AC Input Protection
shut off output
OPP
The over power limit is approximately 105% of the rated output power.
Rising/Falling Voltage Slew Rate: Only applicable if V-I Mode is set to CV Slew Rate Priority.
0.1~80
V/s
Rising/Falling Current Slew Rate: Only applicable if V-I Mode is set to CC Slew Rate Priority.
0.01~60.00
0.01~120.00
0.01~180.00
0.01~60.00
A/s
Output resistance setting
0~1.5
0~0.75
0~0.5
0~1.5
Ω
Efficiency
100Vac
>77
%
200Vac
>79
%
Model
SPS5081X
SPS5082X
SPS5083X
SPS5084X
SPS5085X
units
Output channel
1
2
3
CH
Rated output voltage
80
V
Rated output current
15
30
45
15
A
Total rated output power
360
720
1080
720
1080
W
Power Ratio
3.33
C.V Mode
Line Regulation
40 (From 90 ~ 132Vac or 170 ~ 265Vac, constant load)
mV
Load Regulation
40 (From No load to Full load, constant input voltage)
mV
Ripple and Noise (*1)
(Noise Bandwidth 20MHz; Ripple Bandwidth 1MHz)
RIPPLE (pk to pk)
60
80
100
60
mV
RMS RIPPLE
7
11
14
7
mV
Voltage programming
Accuracy
*0.1%±10
mV
Voltage programming
resolution
1
mV
Voltage Readback Accuracy
*0.1%±20
mV
Voltage Readback resolution
1
mV
Temperature coefficient
100ppm/°C from rated output voltage following 30-minute warm-up.
ppm/
℃