ENCLOSURE: 
¼ DIN, ABS plastic 96 X 96 X 110MM or Nema 4X wall mount 
 

 

FRONT PANEL: 
Gasketed Nema 4X Hinged Window 
 

 

TERMINAL STRIP: 
(24) Removable for ease of wiring 28 – 16 AWG 
 

 

CONNECTIONS: 
Removable screw terminal blocks 28 – 16 AWG wire. (27 with 110VAC option) 
 

 

CPU Activity Monitor 

 

 

PROGRAMMING: 
Menu based, all parameters and setpoints are user configurable via menu prompts and user keys. 
The preconfigured screens and ‘pull down’ sub menus with English prompts assures rapid setup 
and commissioning.  
 

 

1 YEAR WARRANTY 

 

 

4 M/Byte data logging with USB Port 

 

 

MODBUS

® 

Master/Slave

 

Network allows multiple units to be connected together for distributed applications or remote 
monitoring SCADA applications. 
 

 

FEATURES: 
 

 

Microprocessor Based 

 

LCD Display 

 

3 Function Keys 

 

Isolated 24VDC Sensor Power (with 110VAC option) 

 

Fully User Programmable in English 

 

1 Ea. RS485 Port MODBUS

® 

Master/Slave, SCADA 

 

CPU Activity Monitor 

 
 
 
 
 
 
 
 
 
 
 
 
 

Summary of Contents for 700 PDL Series

Page 1: ...1 VISIT OUR WEBSITE SIGMACONTROLS COM 700 SERIES PDL PROCESS DATA LOGGER INSTRUCTION MANUAL 700 SERIES PDL PROCESS DATA LOGGER 062314...

Page 2: ...cess Data Logger Showing Inputs 8 4 20 MA Digital Output 4 Form C Relays PROGRAMMING AND INITIAL SETUP 7 Input Range Selection Terminal Block Detail Initial Setup Programming Overview Key Description...

Page 3: ...ring selection Data logs all variables on user selected interval Provides USB Port for downloading logs ORDERING INFORMATION Wall Mount Nema 4X Enclosure Sigma 700 Series PDL SPECIFICATIONS ANALOG INP...

Page 4: ...e via menu prompts and user keys The preconfigured screens and pull down sub menus with English prompts assures rapid setup and commissioning 1 YEAR WARRANTY 4 M Byte data logging with USB Port MODBUS...

Page 5: ...all local state and national codes that apply Do not exceed the rated current of the D C power supply 100MA or the form C relay outputs 5A 240VAC resistive WARNING Hazardous voltages are present withi...

Page 6: ...6...

Page 7: ...have appeared the unit will show the MAIN SCREEN which scrolls as shown below NOTE To pause the screen scroll press the buttons PROGRAMMING SCREENS From the Main Menu Press the button to access the P...

Page 8: ...bers will change faster with the key held down Move to Screen 2 Press to advance to channel 2 settings Continue with setting channels 2 8 in the same way as described And return to the Main Screen ADV...

Page 9: ...ssword Press to advance to the clock calendar settings Use the buttons to change the month Press to advance Use the buttons to change the year Press to advance Use the buttons to change the other sett...

Page 10: ...he unit NODE number when used in MODBUS Network Press to advance to the input filter screen THE DIAGNOSTIC SCREEN The final menu item is DIAGNOSTICS This screen provides real time information about th...

Page 11: ..._________ Version ________________ Scaling Channel 1 Range _________ Channel 2 Range _________ Channel 3 Range _________ Channel 4 Range _________ Setup Password ___________ Log Interval ___________ C...

Page 12: ...tage is not present check the user supplied power supply or if using the 700 DPCF TPCF supply measure across terminals 24VDC and and If no 24VDC is present consult factory If 24VDC is present check fi...

Page 13: ...LEANED BEFORE RETURNING UNITS RETURNED UNCLEANED WILL BE CONSIDERED UNREPAIRABLE AND RETURNED TO SENDER OR DISCARDED NOTE DO NOT SUBMERGE UNITS FOR CLEANING WITH CABLE CUT OR REMOVED THIS WILL ALLOW C...

Reviews: