background image

12

RECYCLING

 

   Do not dispose of this device or battery in a household waste bin!
  • The electrical and electronic equipment used must be handled separately and in    
    accordance with the legislation, which requires appropriate processing and recycling of  
    the aforesaid goods.
  • The battery contains pollutants and, therefore, after the end of its lifetime, it should not  
    be disposed of in common waste but delivered to the appropriate operator for the 
    collection and disposal of polluting waste in accordance with the local laws and 
   regulations.
  • Recycling of the product will help to avoid potential adverse effects on the environment  

   

  and human health, which could arise from inadequate waste management.

You must regularly test the siren operation. Thus, you will make sure that the siren is functioning 

properly and will sound in case of alarm.

1. Check the proper operation of the siren’s speaker as well as the LED Flash by simulating an  

  alarm from the Control Panel.

2. Check the proper functioning of Tamper switch that protect the siren from opening or 

  detachment from the wall.

3. Check whether the siren’s battery voltage is 13.2-13,8 V. If the battery voltage is lower than  

  this, replace the battery and connect the new battery, keeping in mind to use the correct 

 polarity.

4. Check for signs of water or insects entering the siren and clean if necessary.

Thank you for selecting our products which have been designed and manufactured to offer you security and 
safety for many years. They have been thoroughly tested before reaching your hands, and have passed all 
necessary performance tests. 

All our products are covered by a 6 (SIX) years warranty, for good 

operation,

 from the date of purchase and covers the products that are accompanied by invoice or receipt 

of purchase. This warranty covers the free of charge repair of the device (parts and labor) in case the  
malfunction is due to failure of device itself and not if the failure is cause to any wrong installation, improper 
use or external factors such as lightning, floods, excess power voltage etc.

 Warranty ceases to exist

 if 

the device has been installed or repaired by an unauthorized person. Also, this warranty does not cover the 
losses, failures or injuries that might happen to the secured area, in case of miss operation of the device. 
Finally, our company is not responsible for the correct installation and use of the security system, for which 
solely responsible is the installer.

Commissioning

Warranty

www.sigmasec.gr

Summary of Contents for IRIS PLUS

Page 1: ...1 INSTALLATION MANUAL IRIS PLUS Outdoor self powered siren...

Page 2: ...o protect the battery from overcharging It has short circuit protection on the battery charging of the cables output Also it has overcurrent and short circuit protection for the battery with simultane...

Page 3: ...and foam detector and then you can open the cover of the siren to change the battery or make service without the siren sound The built in FLASH has five high brightness and low power LEDs which are sh...

Page 4: ...tage on this input drops bellow 5 8 V DC Activation from Trigger It is balanced when there are 0VDC on the Trigger input It sounds an alarm if the voltage of power supply is interrupted or if the volt...

Page 5: ...ACTIVATION INPUT 12V FOR FIRE ALARM SIGN INPUT 12V FOR AUDIBLE AND VISUAL VERIFICATION OF THE CONTROL PANEL STATUS TC INPUT 12V FOR TAMPER 3 AXIS ACCELEROMETER AND FOAM DETECTOR CANCELATION FLT OUT LO...

Page 6: ...nect the siren to the panel as explained in the connection terminals on page 5 and the following wiring diagram 6 When you finish cable connections connect the battery to the siren The siren can remai...

Page 7: ...emain open for only 10 seconds and then be deactivated If a fault is detected on the battery the FLT OUT output will remain activated after the end of 10 seconds and until the fault is restored Once t...

Page 8: ...here is a voltage at the siren power input 12V or every five minutes when there is no voltage If during the test the battery voltage is lower than 11 5V we have a low battery voltage indication and if...

Page 9: ...siren will follow If all the LEDs are off then the siren will have no lighting at standby mode To store this setting into memory press the MENU button The LED with the indication L S will turn on Sele...

Page 10: ...twenty four hours the duration of each alarm should be longer than 20 seconds Each time you press SELECT button you will hear the sound of the siren and will turn on or turn off all five LEDs of the...

Page 11: ...urns to standby mode after three minutes without pressing any of the two buttons This function allows you to open the siren for maintenance or to change the battery without the siren being activated b...

Page 12: ...e battery voltage is lower than this replace the battery and connect the new battery keeping in mind to use the correct polarity 4 Check for signs of water or insects entering the siren and clean if n...