background image

 

 

 

 

Publisher: SIGMATEK GmbH & Co KG 

A-5112 Lamprechtshausen 

Tel.: 06274/4321 

Fax : 06274/4321-18 

Email: office@sigmatek.at 

WWW.SIGMATEK-AUTOMATION.COM 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

Copyright ©   2015 

SIGMATEK GmbH & Co KG

 

 

Translation from German 

 

 

All rights reserved. No part of this work may be reproduced, edited using an electronic system, duplicated or dis-
tributed in any form (print, photocopy, microfilm or in any other process) without the express permission. 
 
We reserve the right to make changes in the content without notice. The SIGMATEK GmbH & Co KG is not responsi-
ble for technical or printing errors in the handbook and assumes no responsibility for damages that occur through 
use of this handbook.

 

Summary of Contents for ETT 1962

Page 1: ...ETT 1962 Touch Operating Panel Date of creation 04 08 2015 Version date 18 05 2017 Article number 01 230 1962 E...

Page 2: ...of this work may be reproduced edited using an electronic system duplicated or dis tributed in any form print photocopy microfilm or in any other process without the express permission We reserve the...

Page 3: ...simplified using this terminal A resistive glass touch screen serves as the input medium for process data and parame ters The output is shown on a 19 SXGA TFT color display With the LSE mask editor g...

Page 4: ...nmental Conditions 5 1 5 Display 6 1 6 Control Unit 6 1 7 Miscellaneous 6 2 Mechanical Dimensions 7 3 Chemical Resistance 8 3 1 Touch Interface 8 4 Connector Layout 9 4 1 Front Connector 9 4 2 Status...

Page 5: ...2 18 05 2017 Page 3 8 Wiring Guidelines 17 8 1 Ground 17 8 2 Shielding 17 8 3 ESD Protection 17 8 4 USB Interface Connections 17 9 Process Diagram 18 10 Status and Error Messages 19 11 Cleaning the To...

Page 6: ...ternal remnant data memory 512 kbyte SRAM battery buffered Internal storage device 1 Gbyte microSD card Internal I O no Interfaces 1x USB Host 2 0 Type A front 1x USB Host 2 0 Type A rear on circuit b...

Page 7: ...ensions 360 x 462 x 57 mm W x H x D Weight incl Mounting brackets typically 7 kg 1 4 Environmental Conditions Storage temperature 20 60 C Environmental temperature 0 50 C Humidity 10 90 non condensing...

Page 8: ...ically 2000 1 Brightness typically 300 cd m Angle CR 10 from left and right 89 above and below 89 1 6 Control Unit Touch pad resistive glass foil glass touch panel Active surface 376 3 x 301 1 mm Reso...

Page 9: ...TOUCH OPERATING PANEL ETT 1962 18 05 2017 Page 7 2 Mechanical Dimensions...

Page 10: ...Resistance 3 1 Touch Interface Solution Visual Effect Coal tar oil toluene None Trichloroethylene None Acetone None Alcohol None Benzine None Machine oil None Ammonia None Glass cleaner None Mayonnai...

Page 11: ...TOUCH OPERATING PANEL ETT 1962 18 05 2017 Page 9 4 Connector Layout 4 1 Front Connector X6 USB 2 0 Type A Pin Function 1 5 V 2 D0 3 D0 4 GND...

Page 12: ...exec lsl When the application is running except when controlled through application differently BLINKS In the CLI while processing the autoexec lsl until the application is running OFF When error occ...

Page 13: ...62 18 05 2017 Page 11 4 3 Rear Connectors X1 Power supply 4 pin Phoenix Contact n c do not use X2 Ethernet 10 100 RJ45 Pin Function 1 n c 2 24 V DC 3 GND 4 GND Pin Function BaseT Gbit 1 Tx 2 TX 3 RX 4...

Page 14: ...rk with SIGMATEK hardware to a third party network without trig gering the error mentioned above X4 microSD Card It is recommended that only storage media provided by SIGMATEK CompactFlash cards micro...

Page 15: ...Type A 2 0 4 3 1 Applicable Connectors X1 4 pin Phoenix Contact plug with spring terminal FK MCP 1 5 4 ST 3 5 Included with delivery X2 X3 8 pin RJ45 not included in delivery X5 X6 USB 2 0 Type A not...

Page 16: ...d storage of one year the lifespan of the battery reaches 3 years We recommend however that the battery be replaced every 2 years to ensure optimal performance Battery order number 01 690 055 Company...

Page 17: ...red internally in a battery buffered memory module SRAM 2 Disconnect the ETT 1962 supply After the supply is disconnected the real time clock is buffered for at least 5 minutes after the battery has b...

Page 18: ...new battery with the correct polarity plus side facing the back of the terminal 5 Hang up housing again and screw it 6 Reconnect supply When exchanging the battery caution must be taken to avoid a sh...

Page 19: ...mouse are not equipped with shielded cables These devices are disrupted by ESD and in some instances no longer function Before any device is connected to or disconnected from the terminal the potentia...

Page 20: ...ETT 1962 TOUCH OPERATING PANEL Page 18 18 05 2017 9 Process Diagram...

Page 21: ...e time can be configured using two system varia bles Runtime time remaining SWRuntime pre selected value for the runtime counter Solution Optimize the application s cyclic task Use higher capacity CPU...

Page 22: ...memory module Cause The program memory module is defect The user program is too large The program memory module is missing Solution Exchange the program memory module 08 RESET The CPU has received the...

Page 23: ...Info 20 LOAD The program is stopped and the CPU is currently receiving a new module or project Info 21 UNZUL MODULE The CPU has received a module that does not belong to the project Solution Recompil...

Page 24: ...the correct operating system version 35 MAX IO Reserved 36 MODULE LOAD ERROR The LASAL Module or project cannot be loaded Solution Recompile and download the entire project 37 BOOTIMAGE FAIL URE A gen...

Page 25: ...rred during a floating point operation 60 DIAS RISC ERROR Error from the Intelligent DIASMaster Restart report error to SIGMATEK 64 INTERNAL ERROR An internal error has occurred all appli cations are...

Page 26: ...SRam data Possible Causes SRam configured incorrectly Battery fort he internal program memory supply is empty Solution Analyze log file Event00 log Event19 log Check configuration Change internal pro...

Page 27: ...as made to open an un known table 114 C_OUTOF_NEAR Memory allocation error 115 C_OUT OF_FAR Memory allocation error 116 C_INCOMAPTIBLE An object with the same name already exists but has a different c...

Page 28: ...ETT 1962 TOUCH OPERATING PANEL Page 26 18 05 2017 243 LSL LOAD 252 CONTINUE 253 PRERUN The application is started 254 PRERESET The application is ended 255 CONNECTION BREAK...

Page 29: ...yed onto the cloth and not directly on the terminal The cleaning solution should not be allowed to reach the terminal electron ics for example through the ventilation slots No erosive cleaning solutio...

Page 30: ...ETT 1962 TOUCH OPERATING PANEL Page 28 18 05 2017 12 Disposal To dispose of the product the respective possibly country dependent guidelines must be met and followed...

Page 31: ...4 1 1 Performance Data Table updated Remanent memory 256 512 KB 23 09 2016 12 28 4 3 Rear Connectors 12 Disposal Note microSD Chapter added 23 11 2016 24 10 Status and Error Mes sages Error code 75 ad...

Page 32: ...ETT 1962 TOUCH OPERATING PANEL Page 30 18 05 2017...

Reviews: