SIGMATEK FDD Step By Step Guide Size 5 to 9
7
Eng
D
Removing the finger-guard break-outs
STEP 6: Wire the drive up
When wiring the drive the power, ground and control connections, they should be tightened to the recommended
torque settings shown in the table below:
Table 6-1 Recommended torque settings
Model size
Terminal description
Torque settings
All
Control terminals
0.2 N m (0.15 lb ft)
Relay terminals
0.5 N m (0.37 lb ft)
5
Power terminals
1.5 N m (1.1 lb ft)
Ground terminals
2.0 N m (1.4 lb ft)
6
Power and ground terminals
6.0 N m (4.4 lb ft)
7
Power and ground terminals
12 N m (8.85 lb ft)
8 and 9
Power and ground terminals
15 N m (11.1 lb ft)
A
1
2
2
1
2
1
2
1
2
1
3
2
B
C
D
A: Size 5 to 9
B: Size 5 only
C: Size 6 only
D: Size 7 to 9
Place finger-guard on a flat solid surface and hit relevant
break-outs with hammer as shown (1). For sizes 7 to 9 pliers
can be used to remove the break-outs, grasp the relevant
break-out with the pliers and twist it as shown (3).
Continue until all required break-outs are removed (2).
Remove any flash / sharp edges once the break-outs
are removed.
Finger guard grommets are supplied in the kitbox for size 5
and 6.
Summary of Contents for FDD 3054.00270