Electrostatic Sensitivity
ESD: Electrostatic Sensitive Devices
Semiconductor used in this product may be damaged by electrostatic
discharge. When unpacking or handling the booster, follow precautionary
procedures including use of grounded wrist straps, grounded workbench
surfaces, and grounded floor mats.
Grounding Electrical Instruments and Components
To avoid power supply spark, please perform the grounding connection of the
equipment racks, equipment chassis, and appropriate tools. And make sure
insert the equipment’s power cable into appropriate mains sockets (three pin or
two pin).
In case of three-pin socket, the 3
rd
pin is used for grounding connection, directly
connect the supplied power cable to the mains socket. In case of a two-pin
socket, the green grounding wire provided with the package needs to be
connected to the electrical grounding facility at the power outlet.
In order to avoid equipment damage or human
injury
by lightning, static
electricity and other phenomenon of electricity leakage, Manufacturer suggest
all products must do the electric-discharge of the electrical grounding in setup
process. Power supply components must meet international electro-technical
commissioning safety standards.
1.3 Other Precautions
Only authorized personnel should be allowed to install and operate
the booster.
Make sure that the power is switched off when installing or
disassembling the booster to avoid short circuit or electrical shock
that may result in personal injury or damage to the equipment.
The booster supports mains power for AC110/220V±20%, 50/60Hz.
Please follow this power range to avoid any damage to the
equipment.
A 3-pin mains socket is recommended by Manufacturer to provide
grounding connection for the booster.
RF arrestor is recommended to connect to the booster
’s BTS port.
Please make sure that the warning indicators on the enclosure are
clearly visible for quick detection of alarm conditions.