Troubleshooting
If the range hood or halogen light does not operate
after installation:
1.
Check if the range hood has been plugged in, make
sure that all power has been turned back ON, fused
not blown and all electrical wiring are properly con
QHFWHG
Swap out light assembly to working ones to deter
mine whether it is caused by defective bulbs. See
Replacing the light bulbs
on Page 22.
The range hood vibrates when the blower is on:
2.
The range hood might not have been secured prop
erly on to the ceiling or wall. Check with your in
VWDOOHU
The blower or fan seems weak:
3.
Check that the duct sized used is at least 6” or 3-1/4
x 10”. Range hood WILL NOT function efficiently
with insufficient duct size. For example: 8” duct
over 6” hole and loosely secured.
Check if duct is clogged or if damper unit (half-cir
cular flapper) is not installed correctly or opening
properly. A tight mesh on a side wall cap unit might
also cause restriction to the air flow.
The lights work but the blower is not spinning at all,
is stuck or is rattling.
4.
The blower might be jammed or scraping the bot
tom due to shipping damage. Please contact us im
mediately.
The hood is not venting out properly:
5.
Make sure the distance between the stove top and
the bottom of the hood is within* 28” and 31” in
distance. *
Due to different ceiling height configura-
tions, recommended height may not be applicable
Reduce the number of elbows and length of duct
work. Check if all joints are properly connected,
sealed, and taped.
Make sure the power is on high speed for heavy
cooking.
NOTE:
For all other inquiries, please contact your local reseller.
Purpose of the slots/holes/openings near the top of
the upper chimney:
6.
These slots/holes/openings are used to exhaust
cleaned air with optional re-circulating kit. If you
did not install one, you do not need them.
Page 21