- 35 -
Copyright © 2018-2019 SIGNATURE KITCHEN SUITE.
All rights reserved. Only training and service purposes.
7-8. Communication Error (CO)
Symptom
Check Point
1. CO
1. Check the loose connection
2. Check the Hinge connection
Voltage [V]
CON101
1 pin & 2 pin
11.4~12.6V
CON101
2 pin & 5 pin
4.75 ~ 5.25V
CON101
2 Pin & 3 pin
Not 0V, 5V
CON101
2 pin & 4 pin
Not 0V, 5V
CON5
4 pin & 6 pin
Not 0V, 5V
CON5
4 pin & 8 pin
Not 0V, 5V
SMART
BUZZER
H_SENSOR
DOOR 1 SWITCH
DOOR 2 SWITCH
DOOR 3 SWITCH
DAMPER
HEATER
H_SENSOR
BK
SB
PK
BL/WH
BL/WH
1
1
2
3
3
5
7
9
11
13
15
17
19
21
A
5V
GND
A-
B-
5V
GND
SIG
B
23
25
27
29
31
33
4
2
6
8
10
12
14
16
18
20
22
24
26
28
30
32
34
OUTDOOR SENSOR
RD
GY/WH
BL
BO
WH/RD
BN
BN
STEPPING
MOTOR DAMPER
STEPPING
MOTOR DAMPER
A
A-
B-
B
KNOCK ON
SENSOR 1
YL
BK
RD
1
2
3
5V
GND
SIG
KNOCK ON
SENSOR 2
YL
BK
RD
PR
BO/WH
12V
5V
5V
TX
RX
GND
GND
RX
TX
CON101
5
4
3
2
1
Summary of Contents for SKSCW181RP