When connecting to the battery, please use the enclosed alligator clips. If you decide to modify the output
leads, ensure that the wire diameter is appropriately sized to allow the full output current.
Safety Information
●
If the EG4 Battery Charger appears to be damaged or abnormal, please immediately disconnect the charger
and contact Signature Solar.
●
This charger is not designed to be opened, disassembled, or repaired for any reason. Opening the battery
charger can be dangerous, resulting in electric shock, injury, or even death. Do not open the cover.
●
If there appears to be any damage to the wiring harness, please do not connect the charger or use the
charger. There are locations on the harness where damage may occur if dropped or smashed into. Please
visually inspect prior to use and if there is damage, replace the wiring harness or contact Signature Solar.
Indicator Light
●
Red indicator flashes every second:
Battery Charge <80%
●
Yellow indicator flashes every second:
Battery Charge >80%
●
Green indicator flashes every second:
Battery Charge ~100%
●
Green indicator on:
Battery Charge 100% and not currently charging
*Note: It is not uncommon for LiFePo batteries to register directly from a red indicator to green due to the
charging graph for this type of battery. Do not be alarmed if you do not see the yellow flashing indicator.
** Even when the battery reaches 100%, the charger may still blink red for up to 30 minutes if cell
equalizing is needed.
Fault Indication
●
Red indicator flashes every three seconds: Battery Abnormal
●
Yellow indicator flashes every three seconds:Source Electric Anomaly
●
Green indicator flashes every three seconds: Charger Abnormal
Common Fault Solutions
●
Battery Abnormal
○
Output Short Circuit: Check wire output to verify there is no short circuit
○
No Battery/Reverse Polarity: Check battery connection is secure and correct
○
Battery Low Voltage: Ensure battery voltage is above minimum required for charger
○
Battery Overheat: Ensure proper ventilation and that you are within operating range
●
Source Electric Anomaly
○
Error Input Voltage: Verify input voltage is in the correct range for charger
○
Thin Input Wire Line: Ensure input wire line is of correct size
●
Charger Abnormal
○
Charger Overheat: Verify proper ventilation and allow charger to cool before continued use
Working Environment and Input Characteristics
Item
Technical Target
Working Temperature
-40
℃
to 60
℃
Storage Temperature
-40
℃
to 90
℃
Relative Humidity
5% to 95%
Heat Dissipation Method
Forced Cooling
Input Voltage
AC 90-264V
∓
20%
Input Frequency
45Hz-65Hz