13
TROUBLESHOOTING
The following items are the most common tool symptoms if problems should occur. For
symptoms or remedies not shown, contact your Signode service representative for additional
information and details. The following tool symptoms are shown in this manual:
#1 SYMPTOM: Loose strap between roller stacks.
#2 SYMPTOM: Strap between dispenser and machine too loose following strapping cycle.
#3 SYMPTOM: Loose wraps on strap coil.
#4 SYMPTOM: Dispenser ‘Jerk’ stops.
#5 SYMPTOM: Dispenser ‘Jerk’ starts.
#6 SYMPTOM: Strap pulls out of machine.
#7 SYMPTOM: Dancer arm hits bumper when actuated.
#8 SYMPTOM: Dancer arm swings upward with little or no resistance.
#9 SYMPTOM: Dancer arm motion is erratic.
#1 SYMPTOM: Loose strap between roller stacks.
CAUSE
REMEDY
Dispenser accumulation improperly adjusted.
See Adjustments Section.
#2 SYMPTOM: Strap between dispenser and machine too loose following strapping cycle.
CAUSE
REMEDY
Dispenser accumulation improperly adjusted.
See Adjustments Section.
#3 SYMPTOM: Loose wraps on strap coil.
CAUSE
REMEDY
1.
Brake block pressure too low.
2.
Brake block friction surface worn out.
1.
Increase brake block pressure. See
Adjustments section.
2.
Rotate brake block 90 to new friction
surface. See Adjustment Section. If
brake block is worn on all four sides it
must be replaced. See Parts Removal
and Replacement Section.
#4 SYMPTOM: Dispenser ‘Jerk’ stops.
CAUSE
REMEDY
Brake pressure too high.
Reduce the brake block pressure. See
Adjustments Section.