background image

CANOPY

MOUNT SCREWS

(2 REQD)

CANOPY PLATE

(SEE FIG 1 FOR MOUNT)

POWER MODULE
MOUNT SCREWS

#8-32 (2 REQD)

POWER MODULE
MOUNT SCREWS

#8-32 (2 REQD)

-3-

CANOPY MOUNT

SCREWS

(2 REQD)

TOP OR END MOUNT

1

Follow WALL MOUNT steps 1-3.

2. For battery backup models, connect 2-pin polarized battery plug.
3. See Fig.1 and 2 below. Route LED connector through slot in top of housing and through canopy. 
    Insert 6-32 X 3/4" flat head screws into housing and lock down two nuts firmly. 
    Run flat washers on screws, position canopy, and firmly tighten two lock nuts as shown. 
4. Raise sign to J-box, insert excess wiring and plug into center cavity and secure sign assembly with 
    2 #8-32 color- matched screws supplied.

CHEVRON ARROW SELECTION

1

With backplate removed, place sign face on scratch- free surface.

2.Remove four #8-32 screws and detach two corner brackets and one lower bracket. Retain all 
   screws.
3. Remove lens diffuser and place on scratch- free surface. LED panel and test panel assembly
    (in battery backup models only) can be left in place.
4. Place sign face down on raised wooden blocks (or other scratch- free surface), and carefully knock out 
    selected chevron with hammer and small punch.
5. Place upper edge of lens diffuser against flexible spacers, compress spacers slightly and lower bottom
    edge of diffuser into place next to LEDs. Replace three brackets and continue with installation 

J- BOX

CANOPY PLATE

POWER MODULE

#6-32 LOCKNUT (2 REQD.)

#6 FLAT WASHER (2 REQD.)

#6-32 SMALL PATTERN 
NUT ( 2 REQD)

#6-32 X 3/4" SCREW,
FLAT HD (2 REQD.)

SIGN HOUSING

CANOPY

TOP MOUNT

END MOUNT

AC POWER INPUT
120/277 VAC

CEILING

FIG 1

FIG 2

POWER 

MODULE

ADAPTOR PLATE

1 1/2" SQ. EXTENSION

AC POWER 

INPUT

       120/277 VAC

GRD

J- BOX

W

ALL

Series RPROBB & RPROAC

Rapier Open Face Die Cast LED System
Battery Backup & AC Models

03.15.03

Summary of Contents for RPROAC Series

Page 1: ...ear gas or electric heaters Mount and secure exit sign at a location and height to avoid ready access and tampering by unauthorized persons Exception Floor proximity installations The use of accessory equipment is not recommended by the manufacturer and may cause an unsafe condition Do not use this equipment for other than intended use IMPORTANT SAFEGUARDS READ AND FOLLOW ALL SAFETY INSTRUCTIONS S...

Page 2: ...arp metal blade Drill 3 16 diameter holes at locations noted above For additional support drill out 2 additional 3 16 dia holes at left and right sides on center Locate back plate in position on wall and mark support holes install wall anchors for support screws 5 For battery backup models connect 2 pin polarized battery plug 6 Run LED lamp plug through backplate Attach back cover to j box with 2 ...

Page 3: ...ur 8 32 screws and detach two corner brackets and one lower bracket Retain all screws 3 Remove lens diffuser and place on scratch free surface LED panel and test panel assembly in battery backup models only can be left in place 4 Place sign face down on raised wooden blocks or other scratch free surface and carefully knock out selected chevron with hammer and small punch 5 Place upper edge of lens...

Page 4: ...Disconnect wire nuts or push nut connectors to AC line inputs To replace with new Power Module reverse this sequence 220 VFWAvenue Grasonville MD21638 TEL 410 827 8300 Fax 410 827 8866 sales signtexinc com www signtexinc com Signtex Inc LIGHTING BATTERY DIAGNOSTIC FUNCTIONS Microprocessor programmed to perform tests as follows Continuous Monitoring w 1 Second Sampling Lamp Connections Transfer swi...