background image

11

ROLE Command

1.      Type 

ROLE=M to set the 

Adapter

 to the 

master role. (Type 

ROLE=S to set back to 

the default.)

Figure9

Figure10

2.  Press Enter to see "OK". This means the  

setup is successful.

DIP Command

1.  The default is DIP=N. Type 

DIP=Y to turn 

on the function of the DIP switch, then 

you can manually adjust the S/M switch 

to change it to master or slave mode.

Figure 11

Summary of Contents for ID-SB0111-S1

Page 1: ......

Page 2: ... 300 feet and features auto pairing and selectable Master or Slave mode Key Features and Benefits Full Bluetooth 2 0 EDR compliant Selectable as Slave or Master mode Bluetooth Class 1 100M 300 feet Baud rate up to 921 6Kb s Frequency 2 400 to 2 4835 GHz System Requirements Windows 8 32 64 bit 7 32 64 bit Vista 32 64 bit XP 32 64 bit Server 2003 2008 32 64 bit Server 2008 R2 2000 ...

Page 3: ...l Dipole Antenna USB Cable Battery power line and connector Quick installation guide Layout Figure 1 USB Connector Power source switch Power line connector Reset DCE DTE switch Status LED Power LED Group G NG S slave M master Antenna Connector RS 232 Serial Port ...

Page 4: ...power supply Power LED on Power input is equal or larger than 3 5 Volt Power LED blinking Power input is lower than 3 5 Volt Status LED off No pairing established Status LED on Connection established Status LED fast blinking In 0 1 sec interval Pairing in either slave or master mode In 0 3 sec interval Discoverable in slave mode Status LED slow blinking In 0 9 sec interval Inquring in master mode ...

Page 5: ...t settings press and hold down the reset button for over 3 seconds to get back to the default settings Baud rate 19200 bps Data bit 8 Parity none Stop bit 1 Flow control none Bluetooth PIN code is 1234 To disconnect and reconnect the wireless connection press the reset button quickly USB Connector Connect USB connector with your PC by using the included USB cable for external power supply ...

Page 6: ...se the DCE DTE dip switch to switch between DCE and DTE mode Switch to DTE mode for Data Terminal Equipment PCs for example switch to DCE mode for Data Communication Equipment Modem for example Move the switch in the direction of antenna for DCE and move it in the direction of RS 232 port for DTE Applications Figure3 Figure4 ...

Page 7: ...e the included USB cable to connect the Adapter s mini USB connector to a USB port of your PC B Use a Powered DB9 connector Pin 9 as the power supply This is often used in POS system C Connect the included battery power line to the Adapter s Power Line Connector and connect the other end of the power line to batteries three A AA AAA batteries or one 3 3 7VDC Li Polymer battery See Figure 5 Figure5...

Page 8: ...r is on Once power is confirmed go to the next section for COM port configuration and connection COM Port Configuration 1 Configure the parameters of the COM port through HyperTerminal or other terminal software To configure the adapter initiate HyperTerminal from the Start Menu Note The configuration windows below come from software HyperTerminal For other terminal software the windows may be sli...

Page 9: ...ose the COM port you are using to connect with the Adapter and click OK Name OK Figure 7 OK Select the COM port 4 Confirm the parameters as the following then click OK To pair two devices for an exclusive connection between them ...

Page 10: ...t section Master Slave Mode Setup to set the Adapter mode 5 Enable the bluetooth function of the PC search the Serial Adapter and make a connection to it Master Slave Mode Setup Set the Adapter to be in Master mode or Slave mode through terminal software ROLE command or DIP command Note Slave mode is the default setting ...

Page 11: ...to set back to the default Figure9 Figure10 2 Press Enter to see OK This means the setup is successful DIP Command 1 The default is DIP N Type DIP Y to turn on the function of the DIP switch then you can manually adjust the S M switch to change it to master or slave mode Figure 11 ...

Page 12: ... two RS 232 Serial to Bluetooth Adapters meaning this adapter is able to perform single to multiple transmission Follow the steps to set the adapter to Group mode by terminal software Type DIP Y to turn on the function of the DIP switch After the function of DIP switch has turned on you can adjust the switch to G ...

Page 13: ...e than the time 500ms 500ms 500ms 1500ms Inquire the current setting Default Y Turn on the command N Turn off the command Set the remote adapter change the data mode into command mode from the local adapter in connecting status The command is available after 500 ms when data transferring finished Switch the remote adapter from the data mode to the command The time interval between each character w...

Page 14: ...s in master mode The command is available when DIP N The system will not restart after the change Y The Master role adapter will connect the latest paired Bluetooth device automatically Default N The user will connect the Bluetooth device manually Inquire the current setting BAUD Used to specify the baud rate of COM port The command will have 200ms delay 1200 1200 bps 2400 2400 bps 4800 4800 bps 9...

Page 15: ...f the power supply and set the alert value of low power Y Restore the default settings e g 19200bps The command will restart the system for 1 second DETECT Used to detect the Voltage of the power supply and set the alert value of low power Default N Disable the Voltage detection Y Enable the Voltage detection R Restore the default value 3 5 Volt xx Setup the range of Voltage detection from 3 0 to ...

Page 16: ...e role N The adapter enters the undiscoverable mode If a pair has been made the original connection can be resumed But other remote master device cannot discover this adapter Default Y The adapter enters the discoverable mode Inquire the current setting ECHO This command is used to specify whether the adapter echoes characters received from the UART back to the DTE DCE N Command characters receive...

Page 17: ...arity E Even parity Inquire the current setting PIN Used to designate a PIN The default PIN is 1234 Paired adapters should have the same PIN This command is used to designate a PIN The default PIN is 1234 and the digits should not be less than 4 Paired adapters should have the same PIN The PIN can be set up with combinations of numbers English characters or both Default 1234 xx xx xx xx is a 4 16 ...

Page 18: ... Set the adapter to the slave role Inquire the current role of the adapter RSSI Received signal strength indication Display the strength of signal received in command mode when connected 1 Strong RSSI 9 2 Medium 9 RSSI 20 3 Weak RSSI 20 SEARCH Used to search for any Bluetooth device in the environment within one minute If any device is found its name and its 12 digit address will be listed The sea...

Page 19: ...nd is not available under following status 1 ROLE S SEARCH CONNECT CONNECT P CONNECT xxxxxxxxxxxx CONNECT DEVICE 2 AUTO Y SEARCH CONNECT CONNECT P CONNECT xxxxxxxxxxxx CONNECT DEVICE 3 DIP Y ROLE M ROLE S AUTO Y AUTO N DISCOVER Y DISCOVER N 4 SEARCH CONNECT CONNECT P CONNECT xxxxxxxxxxxx CONNECT DEVICE 5 SEARCH CONNECT CONNECT P CONNECT xxxxxxxxxxxx CONNECT DEVICE 6 Not connection RSSI CONNECT Y C...

Page 20: ...utput Input Transmitting data 3 RxD Input Output Receiving data 4 DSR Input Output Contact manufacturer for set up 5 GND N A N A Signal ground 6 DTR Output Input Contact manufacturer for set up 7 CTS Input Output Clear to send 8 RTS Output Input Request to send Default 9 Vcc Input Input Power supply 5VDC 1 5A Max ...

Page 21: ...e PC with RS 232 port Configure the parameters of RS 232 Serial to Bluetooth Adapter as following Role Slave Dip switch DCE F Baud rate parity stop bits values should be set to the same values as your RS 232 device 2 After the connection between the 2 PCs are established PC with bluetooth will show 2 COM ports Only one of the COM port can work normally 3 If the connection between 2 PCs works well ...

Page 22: ...22 Blank Page ...

Page 23: ...edures below A If it is within the store s return policy period please return the product to the store where you purchased from B If your purchase has passed the store s return policy period please follow the steps below to have the product repaired or replaced Step 1 Submit your RMA request Go to www siig com click Support then REQUEST A PRODUCT REPLACEMENT to submit a request to SIIG RMA or fax ...

Page 24: ...e trademarks of their respective owners Aug 2018 Copyright 2018 by SIIG Inc All rights reserved About SIIG Inc Founded in 1985 SIIG Inc is a leading manufacturer of IT connectivity solutions including Serial ATA and Ultra ATA Controllers FireWire USB and legacy I O adapters that bridge the connection between Desktop Notebook systems and external peripherals SIIG continues to grow by adding A V and...

Reviews: