10
Note
: The disk carrier connector at the back of each
drive carrier slot can be damaged if the drive
carrier is not properly aligned when inserted.
Insert the drive carrier gently to avoid damage.
Figure 10. Inserting the hard disk drive
Hot Swapping Hard Drives
The hot swap function is available on the RAID 5 array.
RAID rebuilding will be processed automatically in the
background and the RAID box will record it's progress. If
the host system is powered off or shutdown abnormally,
the RAID box will continue the disk rebuilding process
after power is turned on again.
Disk Drive Failure
If a disk drive fails, or a key switch is turned off, the red
disk activity indicator of it's disk carrier will light and the
alarm will sound. When this happens you can replace the
failed disk drive with a new one, and then turn the key
switch on.
Summary of Contents for SC-000081-S1
Page 18: ...18 Blank Page...