1. Warranty information
In order to carry out installation correctly, we
strongly recommend this document is read very
carefully. This will ensure your own safety and
the operating reliability of the device.
Your device has been quality controlled, tested
and is ready for use. Please observe all warnings
and information which are marked either directly
on the device or specified in this document.
Warranty can only be claimed for components
supplied by SIKO GmbH. If the system is used
together with other products, there is no warranty
for the complete system.
Repairs should be carried out only at our works.
If any information is missing or unclear, please
contact the SIKO sales staff.
2. Identification
Please check the particular type of unit and type
number from the identification plate. Type number
and the corresponding version are indicated in the
delivery documentation.
e.g. GP09-0023
version number
type of unit
3. Summary description
Geared Potentiometer as an absolute encoder
with analog output.
•
•
•
•
•
The analogue value is available as
- a resistance value or
with instrument transformer
- a current.
4. Installation
For mounting, the degree of protection specified
must be observed. If necessary, protect the unit
against environmental influences such as sprayed
water, dust, knocks, extreme temperatures.
Slide GP09 onto the solid shaft, insert torque pin
into the prebored mounting hole and use grub
screw M4 to fix the GP09's hollow shaft to the
machine's solid shaft (see fig. 1).
Ensure sliding fit between solid shaft and
GP09.
Ensure accurate shaft alignment and mount the
GP09 without force. Ensure that the encoder is
mounted without strain. If the shaft is not cor-
rectly aligned, strain on the bearings will result,
which may cause overheating and irreparable
damage.
Especially when using torque pin type A for
fixing, ensure that GP09 does not jam and that it
is mounted without strain. Please remember this
when choosing the GP09's bore diameter.
Knocks on the unit should be avoided!
•
•
•
•
•
User Information
GP09
Geared Potentiometer
5. Electrical connection
Switch off current before connecting or dis-
conneting unit!!
Wiring must only be carried out with power off.
Provide stranded wires with ferrules.
•
•
•