background image

1 6

MA01/1

Datum 16.11.2001

Art.Nr. 77320

Z.Nr. 8664054

Änd.Stand 389/01

_dP_

decimal point (only if resolution has
been programmed "FrEE") 0. to 0.000

_dIR_

counting direction UP, dn

_dI_E

display of sensor inputs
CH_Add, CH

_A_SEn autom. channel switching (only if

'_dI_E' has been programmed to
"CH") on , oFF

_AUto_

switch-off method 0, 1, 2

PErIod

switch-off time (in seconds) (only for
switch-off methods '1', '2') ... 999

_rSTo__ last value memory on , oFF

_F_AbS access reset function: on , oFF

_F_rEL

access increm. measurement:
on , oFF

_F_rEF

access reference value:
on , oFF

_F_oFF access offset value:

on , oFF

_LAn_

language d, E

0.0

UP

CH

oFF

0

009

oFF

on

oFF

oFF

oFF

d

SIKO GmbH
Dr.-Ing. G. Wandres

Werk / Factory:
Weihermattenweg 2
D-79256 Buchenbach

Postanschrift / Postal address:
Postfach 1106
D-79195 Kirchzarten

Telefon / Phone 0 76 61 / 3 94 - 0
Telefax / Fax

0 76 61 / 3 94 - 388

eMail

info@siko.de

Internet

www.siko.de

Summary of Contents for MA01/1

Page 1: ...ont platte ausrichten und Schraube festziehen Benutzerinformation MA01 1 Magnetbandanzeige DEUTSCH 1 Gewährleistungshinweise LesenSievorderMontageundderInbetrieb nahme dieses Dokument sorgfältig durch Be achten Sie zu Ihrer eigenen Sicherheit und der BetriebssicherheitalleWarnungenundHinwei se Ihr Produkt hat unser Werk in geprüftem und betriebsbereitem Zustand verlassen Für den Betrieb gelten die...

Page 2: ...teten Reglern oder Schützen vermindertwerden 1 2 3 ErforderlicheMaßnahmen Nur geschirmtes Kabel verwenden Den Ka belschirmbeidseitigauflegen Litzenquerschnitt der Leitungen min 0 14 mm max 0 5 mm Die Verdrahtung von Abschirmung und Mas se 0V muss sternförmig und großflächig erfol gen Der Anschluss der Abschirmung an den Potentialausgleichmussgroßflächig niederim pedant erfolgen Das System muss in ...

Page 3: ...afmodemöglich Ruhemode standby Die Anzeige wird nach einer bestimmten Zeit nach der letzten Messung dunkel Der Strom verbrauchistzurSchonungderBatterien Akkus reduziert Neuaktivierung durch Sensorbewe gung oder durch Betätigung der Taste Schlafmode sleepmode Anzeige schaltet automatisch nach der letzten Messung ab Die Batterien Akkus werden mit einemminimalenErhaltungsstrombelastet Neu aktivierung...

Page 4: ...iermodus geschaltet werden siehe unten SiekönnendieParameterjederzeitändernoder kontrollieren Die von Ihnen gewählten Werte werdennichtflüchtiggespeichert DieParameter unterscheiden sich zwischen der Einkanal und derZweikanal Version 1Sensoroder2Senso ren DieUnterschiedesindinderParameterliste beschrieben Die Bezeichnung Funktion und wählbaren Werte finden Sie in den folgenden Tabellen Eintritt in...

Page 5: ...ige _A_SEn AutomatischeKanalumschaltung nurbeiZweikanal Versionundbei Einzelanzeige _dI_E CH AUS unwirksam nur manuelles Um schalten möglich EIn wirksam manuelles Umschalten weiterhinmöglich _AUto_ Abschaltart Betriebsart der automatischenAbschaltung 0 0 keine Abschaltung 1 1 Ruhemode stand by 2 2 Schlafmode sleep mode jeweils nach der Abschaltezeit PErIod PErIod Abschaltzeit s Zeit zwischen letzt...

Page 6: ...weikanal Version zeigen im Display zusätzlich ein oder zweileuchtendeLEDsan obsichderangezeig te Wert auf den Sensor 1 oder 2 bezieht Um schaltung der Eingänge durch Taste Abb 9 Sensoranzeige bei Zweikanalversion 11 Istwertspeicher Voraussetzung _ISP_ EIn Versorgung10 30VDC 110VACund230VAC BeiAusschaltenderSpannungsversorgungoder Abschalten des Gerätes durch ON OFF Taste wirdderzuletztangezeigteMe...

Page 7: ...ängenmessung Anforderungen Anzeigegenauigkeit1 10mm Anzeige soll über Fronttaste genullt werden können Bezeichnung Anzeige progr Wert Auflösung _AUFL_ 0 1 Referenzwert _rEF_ 00000 0 Offset _oFF_ 00000 0 Nachkommastelle _dP_ 0 0 Zählrichtung _ZAEHL AUF Abschaltart _AUto_ 0 Istwertspeicher _ISP_ AUS FreigabeReset _F_Abs EIn Freig Kettenmaß _F_rEL AUS Freig Ref _F_rEF AUS Freig Offset _F_oFF AUS Spra...

Page 8: ..._AUFL_ Aulösung mm In inch 1 0 1 0 05 0 01 In 0 01 In 0 1 FrEI _FAC_ Rechenfaktor nur bei Auflösung FrEI 0 00001 0 99999 _rEF_ Referenzwert 999999 999999 _oFF_ Offsetwert 999999 999999 _dP_ Nachkommastelle nurbei Auflösung FrEI 0 bis 0 000 _ZAEHL Zählrichtung AUF Ab _dI_E AnzeigeSensoreingänge CH_Add CH _A_SEn Autom Kanalumschaltung nur bei _dI_E CH EIn AUS _AUto_ Abschaltart 0 1 2 PErIod Abschalt...

Page 9: ... sales staff 2 Identification Please check particular type of unit and type number from the identification plate Type num berandthecorrespondingversionareindicated in the delivery documentation e g MA01 1 0023 versionnumber type of unit User Information MA01 1 Electronic Display 3 Installation Formounting thedegreeofprotectionspecified must be observed If necessary protect the unit against environ...

Page 10: ...rference eg interferencecausedbySMPS motors cyclic controls and contactors Necessarymeasures Only screened cable should be used Wire cross section is to be at least 0 14 mm max 0 5 mm Wiring to screen and to ground 0V must be viaagoodearthpointhavingalargesurfacearea for minimum impedance The unit should be positioned well away from cables with interference if necessary a protec tive screen or met...

Page 11: ...ators Thedisplayis reactivated as soon as the sensor moves or by pressing key active Sleep mode Afterthelastmeasurementthedisplayswitches offcompletely Powerconsumptionofthebatte ries accumulators is reduced to a minimum Press key ON OFF to reactivate the display The display can be completely switched on off if it is temporarily not needed Switch off Press key ON OFF Switch on Active mode Press ke...

Page 12: ... Press key for at least 5 s Toleaveprogrammingmode Automatically ifnokeyhasbeenpressedduring approx 30 s or if you press until the end of the parameter list is reached To scroll the parameters Press key To modify parameters Use keys and To store modified parameters Press key the display will shortly show the message Sto 8 Parameter description At the end of this user information brochure you will ...

Page 13: ... memory off When switched on the display must be calibrated zeroed on Last value memory on When switched on the last measured value is displayed _F_AbS Access reset function resetting to reference value via key on front of the display in case of 2 channel MA01 1always on oFF Reset function off on Reset function on _F_rEL Access incremental measurement to switch from absolute dimension and zero set...

Page 14: ...alue memory 12 Referencing During referencing the counter is set to the programmed reference value and this value is displayed MA01 1 can thus be zeroed if the reference value was previously programmed to 0 Forreferencing orzeroing press key for 1 channel MA01 1 BrieflyactivateinputREF contactagainstGND eg by a switch or push button with closing function MA01 1 always has to be calibrated before t...

Page 15: ...alue _rEF_ 00000 0 Offset _oFF_ 00000 0 Decimalpoint _dP_ 0 0 Countingdirection _dIr_ UP Switch off method _AUto_ 0 Last value memory _ISP_ oFF Access reset _F_Abs on Access increm meas _F_REL oFF Access ref value _F_rEF oFF Access offset _F_OFF oFF Language _LAn_ E I II Standardprogr your programming 0 1 0 00000 00000 0 00000 0 0 0 UP 0 1 0 00000 00000 0 00000 0 Display Designation valuerange SEn...

Page 16: ...itch off time in seconds only for switch off methods 1 2 999 _rSTo__ last value memory on oFF _F_AbS access reset function on oFF _F_rEL access increm measurement on oFF _F_rEF access reference value on oFF _F_oFF access offset value on oFF _LAn_ language d E 0 0 UP CH oFF 0 009 oFF on oFF oFF oFF d SIKO GmbH Dr Ing G Wandres Werk Factory Weihermattenweg2 D 79256Buchenbach Postanschrift Postaladdr...