MA504/1

Battery change English

MA504/1 · Date 

10.05.2016 · Art. 

No. 

85793 · Mod. 

status 

242/15

16

Basically, all connections are protected against external interference. 

Choose a place of operation that excludes inductive or capacitive inter-

ference influences on the electronic display. When mounting the system 

keep a maximum possible distance from lines loaded with interference. If 

necessary, provide additional installations including screening shields or 

metallized housings.

Connection sensor

Connect the sensor to the MA504/1 via the 8-pin jack (see 

Fig. 3

). Sensor 

mounting as well as laying of the sensor cable are described in the User 

Information for the sensor MS500H.

Connection power supply

Battery powered.

1

  Sensor connection

2

  Battery case

Fig. 3: Connection

5  Battery change

Inflammable, danger of explosion and burns

 

`

Do not recharge the battery nor expose it to temperatures above 

85 °C.

 

`

Dispose of used batteries properly.

When exchanging the batteries take care that their polarity is correct! 

Take the marking on the bottom of the box as orientation.

Battery types

Batteries are not supplied together with the MA504/1. The following stan-

dard types can be used:

2 x Micro / AAA

NOTICE

DANGER

NOTICE

Summary of Contents for MA504/1 Software S

Page 1: ...242 15 MA504 1 Magnetbandanzeige Originalmontageanleitung Deutsch Seite 2 Magnetic display Translation of the Original Installation Instructions English page 11...

Page 2: ...m e Verwendung 3 2 2 Kennzeichnung von Gefahren und Hinweisen 3 2 3 Zielgruppe 4 2 4 Grundlegende Sicherheitshinweise 5 3 Identifikation 5 4 Installation 5 4 1 Mechanische Montage 5 4 2 Montage Magnet...

Page 3: ...Verarbeitung und Ausgabe von Positionswer ten Die MA504 1 darf ausschlie lich zu diesen Zwecken verwendet wer den Die Magnetbandanzeige ist nur f r die Verwendung im Industriebe reich vorgesehen die k...

Page 4: ...lb der Antriebstechnik verf gt Die ser Personenkreis ben tigt fundierte Kenntnisse ber die notwendigen Anschl sse einer Magnetbandanzeige und deren Integration in die kom plette Maschinenanlage Nicht...

Page 5: ...em beeinflussen Sch tzen Sie den Magnetbandanzeige vor Einfl ssen von Fremdmag neten 3 Identifikation Das Typenschild zeigt den Ger tetyp mit Variantennummer Die Lieferpa piere ordnen jeder Variantenn...

Page 6: ...Befestigungslaschen wird die Anzeige gehal ten kann aber auch leicht demontiert werden Abb 2 Montage 1 Schalttafel 4 3 Elektrische Installation Zerst rung von Anlagenteilen und Verlust der Steuerungsk...

Page 7: ...504 1 erfolgt ber die 8 polige Buchse siehe Abb 3 Die Montage des Sensors sowie die Verlegung des Sensorkabels wird in der Benutzerinformation zum Sensor MS500H erl u tert Anschluss Spannungsversorgun...

Page 8: ...gibt zwei Betriebsarten in denen das Ger t mittels der Tastatur beein flusst werden kann 1 Programmiermodus Einmalige Einrichtung der Anzeige auf die Anwendung 2 Eingabemodus Funktionen die w hrend d...

Page 9: ...llen gesammelt und auf umweltfreundliche Weise entsorgt werden Nur f r EU L nder Gem der Richtlinie 91 157 EWG m ssen defekte oder verbrauchte Batterien recycelt werden 8 Technische Daten Mechanische...

Page 10: ...m 1 Digit Verfahrgeschwindigkeit 5 m s bei Leseabstand 0 1 2 mm Umgebungsbedingungen Erg nzung Umgebungstemperatur 0 60 C Lagertemperatur 10 70 C relative Luftfeuchtigkeit 95 Betauung nicht zul ssig E...

Page 11: ...d use 12 2 2 Identification of dangers and notes 12 2 3 Target group 13 2 4 Basic safety information 13 3 Identification 14 4 Installation 14 4 1 Mechanical mounting 14 4 2 Mounting the electronic dis...

Page 12: ...processing and output of position values The MA504 1 must be used for such purposes exclusively The electronic display is only intended for use in industrial applications that are not sub ject to spec...

Page 13: ...ualified personnel Insufficiently qualified personnel cause personal injury serious damage to machinery or electronic display Configuration commissioning mounting and maintenance by trained expert per...

Page 14: ...he corresponding version are indicated in the delivery documentation e g MA504 1 0023 variant number type of unit 4 Installation 4 1 Mechanical mounting Failure of the electronic display When mounting...

Page 15: ...nting tabs hold the unit but allow easy removal too Fig 2 Mounting 1 Panel 4 3 Electrical installation Destruction of parts of equipment and loss of regulation control All lines for connecting the ele...

Page 16: ...he sensor to the MA504 1 via the 8 pin jack see Fig 3 Sensor mounting as well as laying of the sensor cable are described in the User Information for the sensor MS500H Connection power supply Battery...

Page 17: ...e via the keyboard 1 Programming mode One time adjustment of the display to the appli cation 2 Input mode Functions required during normal operation 7 Transport Storage Maintenance and Disposal Transp...

Page 18: ...cled accord ing to Directive 91 157 EEC 8 Technical data Mechanical data Additional information Housing design built in housing plastic switchboard cutout 67 3 x 33 5 0 3 Weight 0 07 kg Electrical dat...

Page 19: ...itions Additional information Ambient temperature 0 60 C Storage temperature 10 70 C Relative humidity 95 condensation inadmissible EMC EN 61000 6 2 interference resistance immis sion EN 61000 6 4 emi...

Page 20: ...g 2 79256 Buchenbach Telefon Phone 49 7661 394 0 Telefax Fax 49 7661 394 388 E Mail info siko de Internet www siko global com Service support siko de nderungen vorbehalten Subject to technical alterna...

Reviews: