MA505
Datum 25.09.2008
Art.Nr. 80475
Änd. Stand 369/08
5
Fig. 1: Installation
ENGLISH
1. Warranty information
In order to carry out installation correctly, we
strongly recommend this document is read very
carefully. This will ensure your own safety and
the operating reliability of the device.
Your device has been quality controlled, tested
and is ready for use. Please respect all warnings
and information which are marked either directly
on the device or specified in this document.
Warranty can only be claimed for components
supplied by SIKO GmbH. If the system is used
together with other products, there is no warranty
for the complete system.
Repairs should be carried out only at our works.
If any information is missing or unclear, please
contact the SIKO sales staff.
2. Identification
Please check particular type of unit and type num-
ber from the identification plate. Type number and
the corresponding versionare indicated in the de-
livery documentation.
eg. MA505-0023
version number
type of unit
3. Installation
For mounting, the degree of protection specified
must be observed. If necessary,protect the unit
against environmental influences such as sprayed
•
•
•
•
water, dust, knocks, extreme temperatures.
Attention! Systeminformation! Only when com-
bined with sensor MSA!
Before mounting sen-
sor and/or magnetic tape, please read chapter 6
(sensor alignment) and ensure that: the necessary
alignment length is available; that sensor and ma-
gnetic tape are aligned correctly.
Built-in housing EG
Push the device into the panel (1) until the panel
clips (2) hold the housing loosely.
Press the lateral centering (3) slightly down and
push the housing into the cut-out (1) until the
panel clips (2) snap completely.
•
•
User Information
MA505
Electronic Display absolute
Bench housing TG, TG/DV
The rubber feet can be removed in order to screw
down the unit.
Attention!
Maximum screw insert depth of 6,5mm
must be strictly adhered to!
4. Electrical connection
Switch power off before any plug is inserted
or removed!
Wiring must only be carried out with power off!
Provide standed wires with ferrules.
Check all lines and connections before switching
on the equipment.
Interference and distortion
All connections are protected against the effects
of interference.
The location should be selected
to ensure that no capacitive or inductive in-
terferences can affect the display or the con-
nection lines!
Suitable wiring layout and choice
of cable can minimise the effects of interference
(eg. interference caused by SMPS, motors, cyclic
controls and contactors).
Necessary measures
Only screened cable should be used. Wire cross sec-
tion is to be at least 0,14mm², max. 0,5mm².
Wiring to screen and to ground (0V) must be via
•
•
•
•
•
•