Operating manual - English
Optika
18
Copyright Silca 2017
Fig. 22
-
Before confirming the reading, press the ENTER button and make sure the key is actually aligned
(the top yellow bar should be just a vertical line and the left-hand yellow bar should point upwards as
much as possible).
-
A downward arrow on the insertion bar (left) indicates that the key has been inserted too far inside.
It is advised to gradually pull out the key until the arrow no longer appears.
-
Press the ENTER push button and the display will show a new image.
6.1.3
STEP 2: VIEWING THE PROFILE
Fig. 23
If the left-hand bar (referred to the luminosity of the profile) on the display is not
completely upwards, lightly push the key head so that it advances well into the
clamp, or pull it out slightly.
The end of milled channels must be beneath the illuminators in any case. So-
metimes the profile and the surface condition of the key do not allow it to ex-
tend completely (the left-hand bar could be half-way). With a left-hand bar below
70% of the total, key recognition is either not good and/or wrong.
If the upper bar is not a thin line on the display, turn the clamp/key slightly right
or left until it reaches the best possible condition.
However, it is important that the outline of the profile is well defined; at ti-
mes it is necessary to find a compromise between the thickness of the up-
per alignment bar and the image of the profile.
stop detector line
key alignment bar
key alignment bar
ENTER
ENTER
L:2419
L:2707
key-fitting bar
left-hand bar (profile luminosity)
left-hand bar (profile luminosity)
ENTER
ENTER