Rev. 1.3
199
C8051F340/1/2/3/4/5/6/7/8/9/A/B/C/D
Figure 17.5. Typical Master Transmitter Sequence
A
A
A
S
W
P
Data Byte
Data Byte
SLA
S = START
P = STOP
A = ACK
W = WRITE
SLA = Slave Address
Received by SMBus
Interface
Transmitted by
SMBus Interface
Interrupt
Interrupt
Interrupt
Interrupt