7.2.4.3. Phase Noise
1. Set the Spectrum analyzer to “Phase Noise”.
2. Set the center frequency of spectrum analyzer to the frequency selected.
3. Set the spectrum analyzer to the desired span (typically from 100 Hz to 10 MHz span).
Figure 36. Typical Phase Noise Plot at 917 Mhz
7.2.5. PN9 Measurement
Using the PN9 Lab Mode, users may evaluate the following:
1. Tx output spectrum
2. Transmitter spectral mask
7.2.5.1. Test Method
Figure 37. Setup Screen (1 of 4)
1. Ensure “Lab Mode” is selected as the operating function.
2. Select PN9.
3. Press <GO> to move on from this screen.