Rev. 1.2
281
C8051T620/1/6/7 & C8051T320/1/2/3
timeout interval of 256 PCA clock cycles, or 3072 system clock cycles. Table 29.3 lists some example time-
out intervals for typical system clocks.
29.5. Register Descriptions for PCA0
Following are detailed descriptions of the special function registers related to the operation of the PCA.
Table 29.3. Watchdog Timer Timeout Intervals
1
System Clock (Hz)
PCA0CPL4
Timeout Interval (ms)
12,000,000
255
65.5
12,000,000
128
33.0
12,000,000
32
8.4
24,000,000
255
32.8
24,000,000
128
16.5
24,000,000
32
4.2
1,500,000
2
255
524.3
1,500,000
2
128
264.2
1,500,000
2
32
67.6
32,768
255
24,000
32,768
128
12,093.75
32,768
32
3,093.75
Notes:
1.
Assumes SYSCLK/12 as the PCA clock source, and a PCA0L value
of 0x00 at the update time.
2.